Available documentation
Tech Sheet
- Tech Sheet W11340823 RevA2 pg
- Tech Sheet - 820529316 pg
- Tech Sheet - W1037157520 pg
- Wiring Sheet - W10763000 - Rev B2 pg
- Tech Sheet - W10419696 - Rev A28 pg
- Commercial Microwave Technical Information10 pg
- Tech Sheet16 pg
Tech Tip
- Instruction Sheet - 818443020 pg
- Instruction Sheet - 816969620 pg
Installation Guide
- Installation Instructions9 pg
- Installation Instructions75 pg
- Installation Instructions30 pg
- Installation Instructions33 pg
- Installation Instructions30 pg
MyPros+ Max
Diagnose your Amana RC-10B-PB.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (46)
CodeMeaning
:Flashing colon indicates a power failure has occurred.bFIce maker self-diagnosticsE1Ice maker self-diagnosticsE2Ice maker self-diagnosticsE3Ice maker self-diagnosticsE4Ice maker self-diagnosticsF1.E1Relay control board defective.F1E0EEPROM Communication ErrorF1E1Upper RTD UncalibratedF1E2Lower RTD UncalibratedF1E5Sensor Usage Out of RangeF1E7PCB Thermistor Open or ShortedF1E9WIDE Queue FullF2Touch panel failure.F2.H1Hood keys stuck.F2.H2Hood/light switch defective.F2.Q1Not reading keypad inputs.F2E0Keypad DisconnectedF2E1Stuck KeypadF2E2Cancel or Off Keypad ErrorF3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T2FC (forced convection) thermistor failure.F3.T4Magnetron thermistor failure.F3E0Main Sensor Open or Shorted (Upper)F3E1Main Sensor Open or Shorted (Lower)F3HHumidity sensor failure.F4E1Low Fan Speed UnderspeedF4E4Microwave Oven Humidity Sensor Open or ShortedF5E0Door and Latch Switches Do Not AgreeView all 46 error codes
F5E1Latch Not OperatingF6MW relay failure.F6E0Lost Communication with MicrowaveF6E1Over Temperature CookF6E2Over Temperature CleanF7Power to magnetron interrupted.F8E0Low Fan Speed OverspeedF8E1Microwave Oven Magnetron Thermistor Open or ShortedF8E2High Fan Speed UnderspeedF8E3High Fan Speed OverspeedF9Relay control board communications error.F9.QTouch communication error.F9E0MiswiredOPThermistor is open, displayed during service test thermistor readings.PAIce maker self-diagnosticsSHThermistor is shorted, displayed during service test thermistor readings.
Service modes (7)
- Diagnostic ModePress CANCEL > CANCEL > START or OFF > OFF > ON within 5 seconds.
- Diagnostic SubmenusOnce in Diagnostic mode, press TEMP/TIME '+' or '-' or 'More' or 'Less' keypads or the number 3 or…
- Service Diagnostics Mode["On the Main (Eyebrow) UI, press and hold both temperature '-' buttons simultaneously for 3…
- Test Mode (Diagnostic)["1
- Test Mode (Touch Panel and Relay Control Board Tests)["1
- Touch Panel and PCBA Self-Diagnostic Test Mode["1
- Touch Panel Test Mode["1
Full entry steps, exit procedures, and test sequences are available in Max.