3 documents43 error codes69 service modes
Available documentation
Service Manual
- Consumer Services Technical Education Group Presents KM-30 Microwave Oven Hood Combination54 pg
- Job Aid - Whirlpool Microwave Oven Hood Combination54 pg
Tech Tip
- Instruction Sheet W11420067 - Rev A1 pg
MyPros+ Max
Diagnose your Amana RC-10PB/P71304-2M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (43)
CodeMeaning
afLow inlet air flow condition detected at installation.E0No errors, functioning ice maker.E1No coolingE2Motor lost positionE3Heater time-outE4Dry cycleE5Ice maker thermistor is badE6Manufacturing codeErManufacturing codef:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).View all 43 error codes
f:78Console electronics failure (F:72 through F:78).F1E1Primary control failure.F2Touch panel failure.F2E1Stuck button or user interface mismatch (keypad/user interface failure)F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF3HHumidity sensor failure.F6Microwave relay failure.F8E1No voltage detected at the water valve relay (steam models only)l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (69)
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
- Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostics Mode["Ensure refrigerator is not in lockout mode.","Press SW1 and SW2 simultaneously for 3…
- Service Test - 38 Forced Defrost ModeWhile in Service Diagnostics Mode, navigate to step 38. Select SW3 to set mode
- Service Test 1 - FC Thermistor["Enter Service Diagnostics Mode.","Navigate to step 1 (display shows 01).","The board will…
- Service Test 11 - Dispenser Lighting["Enter Service Diagnostics Mode.","Navigate to step 11.","Pressing SW3 will change the dispenser…
- Service Test 15 - Ice Level Sensor["Enter Service Diagnostics Mode.","Navigate to step 15.","Displays the Ice Bin Status in real time…
- Service Test 16 - RC Left Door Switch Input["Enter Service Diagnostics Mode.","Navigate to step 16.","Displays the RC Door status in real time…
- Service Test 17 - RC Right, Pantries, FC Doors Switch Input["Enter Service Diagnostics Mode.","Navigate to step 17.","Displays the FC Door status in real time…
- Service Test 18 - Ice Door Motor["Enter Service Diagnostics Mode.","Navigate to step 18.","Press ice paddle and verify that the…
- Service Test 19 - Ice Maker Fill Tube Heater Status["Enter Service Diagnostics Mode.","Navigate to step 19.","Control the Ice Maker Fill Tube Heater…
- Service Test 2 - RC Thermistor["Enter Service Diagnostics Mode.","Navigate to step 2.","The board will automatically check the…
- Service Test 20 - Water Filter Usage Rating["Enter Service Diagnostics Mode.","Navigate to step 20.","Displays in two sequential flashes the…
- Service Test 21 - Water Filter Time Rating["Enter Service Diagnostics Mode.","Navigate to step 21.","Displays in two sequential flashes the…
- Service Test 22 - Water Filter Usage["Enter Service Diagnostics Mode.","Navigate to step 22.","Displays in two sequential flashes the…
- Service Test 23 - Water Filter Time["Enter Service Diagnostics Mode.","Navigate to step 23.","Displays in two sequential flashes the…
- Service Test 24 - Water Filter Reset["Enter Service Diagnostics Mode.","Navigate to step 24.","Displays in two sequential flashes the…
- Service Test 26 - Main Control Software Version["Enter Service Diagnostics Mode.","Navigate to step 26.","Displays in three sequential flashes the…
- Service Test 27 - Dispenser UI Control Software Version["Enter Service Diagnostics Mode.","Navigate to step 27.","Displays in three sequential flashes the…
- Service Test 29 - Low Voltage IDI Software Version["Enter Service Diagnostics Mode.","Navigate to step 29.","Displays in three sequential flashes the…
- Service Test 3 - Evaporator Fan Motor and Air Baffle Motor["Enter Service Diagnostics Mode.","Navigate to step 3.","Depress SW3 to cycle
- Service Test 31 - Touch Input Module Software["Enter Service Diagnostics Mode.","Navigate to step 31.","Displays in three sequential flashes the…
- Service Test 32 - Ambient Thermistor UI Control["Enter Service Diagnostics Mode.","Navigate to step 32.","Internal board test
- Service Test 33 - Humidity Sensor UI Control["Enter Service Diagnostics Mode.","Navigate to step 33.","Relative Humidity Test
- Service Test 34 - Vertical Mullion Heater Mode["Enter Service Diagnostics Mode.","Navigate to step 34.","Set the Vertical Mullion Heater Sensor…
- Service Test 35 - Vertical Mullion Heater Status["Enter Service Diagnostics Mode.","Navigate to step 35.","Control the Vertical Mullion Heater…
- Service Test 36 - Ice Box Fan["Enter Service Diagnostics Mode.","Navigate to step 36.","Control Ice Box Fan using SW3
- Service Test 37 - Ice Box Thermistor["Enter Service Diagnostics Mode.","Navigate to step 37.","The board will check the resistance…
- Service Test 38 - Forced Defrost Mode["Enter Service Diagnostics Mode.","Navigate to step 38.","Set the Forced Defrost Mode by selecting…
- Service Test 39 - RC Evap Thermistor["Enter Service Diagnostics Mode.","Navigate to step 39.","The board will check the resistance…
- Service Test 4 - Compressor/Condenser Fan Motor/Evaporator Fan["Enter Service Diagnostics Mode.","Navigate to step 4.","There will be a delay of 3 seconds before…
- Service Test 40 - Horizontal Mullion Heater Mode["Enter Service Diagnostics Mode.","Navigate to step 40.","Set the Horizontal Mullion Heater Sensor…
- Service Test 41 - Horizontal Mullion Heater Status["Enter Service Diagnostics Mode.","Navigate to step 41.","Control the Horizontal Mullion Heater…
- Service Test 42 - UI EEPROM Control Software Version["Enter Service Diagnostics Mode.","Navigate to step 42.","Displays in three sequential flashes the…
- Service Test 45 - Ice Maker Water Fill Test["Enter Service Diagnostics Mode.","BEFORE INITIATING THIS TEST, GO TO STEP 57, INITIATE ICE MAKER…
- Service Test 46 - Water Dispensing Test["Enter Service Diagnostics Mode.","Navigate to step 46.","Press the water pad to initiate a water…
- Service Test 5 - Compressor Status/Speed["Enter Service Diagnostics Mode.","Navigate to step 5.","Initial Display
- Service Test 56 - Ice Maker Error Codes["Enter Service Diagnostics Mode.","Navigate to step 56.","Displays active Ice Maker Error Codes on…
- Service Test 57 - Ice Maker Harvest["Enter Service Diagnostics Mode.","Navigate to step 57.","Press SW3 to activate a Harvest sequence
- Service Test 58 - Ice Maker Heater Activation and Thermistor["Enter Service Diagnostics Mode.","Navigate to step 58.","Press SW3 to activate the Ice Maker…
- Service Test 59 - Ice Maker Motor["Enter Service Diagnostics Mode.","Navigate to step 59.","Press SW3 to activate a Motor sequence…
- Service Test 60 - Pantry UI Software Version["Enter Service Diagnostics Mode.","Navigate to step 60.","Displays in three sequential flashes the…
- Service Test 63 - All Pantry UI Indicators["Enter Service Diagnostics Mode.","Navigate to step 63.","All pantry LED indicators and pantry UI…
- Service Test 64 - Pantry UI Button Test["Enter Service Diagnostics Mode.","Navigate to step 64.","Displays the pantry UI Buttons status."]
- Service Test 65 - Pantry Thermistor["Enter Service Diagnostics Mode.","Navigate to step 65.","The board will check the resistance…
- Service Test 66 - Manufacturing Codes["Enter Service Diagnostics Mode.","Navigate to step 66.","Displays the active manufacturing error…
- Service Test 67 - Water Filter Switch Status["Enter Service Diagnostics Mode.","Navigate to step 67.","Displays the water filter switch status…
- Service Test 73 - Pantry Heater Status["Enter Service Diagnostics Mode.","Navigate to step 73.","Control the Pantry Heater selecting SW3…
- Service Test 76 - Icebox Fascia Heater["Enter Service Diagnostics Mode.","Navigate to step 76.","Control the Icebox Fascia Heater…
- Service Test 77 - Defrost Thermistor["Enter Service Diagnostics Mode.","Navigate to step 77.","The board will check the resistance…
- Service Test 78 - Pantry UI Flashmap Version["Enter Service Diagnostics Mode.","Navigate to step 78.","Displays in three sequential flashes the…
- Service Test 8 - All UI Indicators["Enter Service Diagnostics Mode.","Navigate to step 8.","All LED indicators and UI display digits…
- Service Test 80 - LED Driver Software Version["Enter Service Diagnostics Mode.","Navigate to step 80.","Displays in three sequential flashes the…
- Service Test 81 - LED Driver Flash Software Version["Enter Service Diagnostics Mode.","Navigate to step 81.","Displays in three sequential flashes the…
- Service Test 9 - UI Button and Pad Test["Enter Service Diagnostics Mode.","Navigate to step 9.","Displays the user Interface Buttons and…
- Touch Panel and Electronic Control Self-Diagnostic Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.