mypros+
Model reference

Amana RC-10SE/P76881-1M

Microwave

3 documents48 error codes22 service modes

Available documentation

Tech Sheet

  • Tech Sheet 8543719 110 2506650016 pg
    Covers this model

Service Manual

  • Instruction Sheet - 854371916 pg
    Covers this model

Installation Guide

  • Installation Instructions7 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RC-10SE/P76881-1M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (48)

CodeMeaning
afLow inlet air flow condition detected at installation.CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…E0No errors, functioning ice maker.E1No CoolingE2Motor Lost PositionE3Heater Time-outE4Dry CycleE5IM Bad ThermistorErProcessor reset error; the control failed to save cycle information during a…f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).
View all 48 error codes

Service modes (22)

  • Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
  • Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
  • Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
  • Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
  • Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
  • Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
  • Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
  • Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
  • Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
  • Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
  • Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
  • Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
  • Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
  • Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
  • Service Diagnostics ModePress SW1 and SW2 simultaneously for 3 seconds
  • Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
  • User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass