Model reference
Amana RC-10S/P73829-4M
Microwave
4 documents81 error codes41 service modes
Available documentation
Service Manual
- Commercial Microwave Oven Base Manual42 pg
- MENUMASTER COMMERCIAL MICROWAVE OVEN Service Manual38 pg
- Service Manual - Commercial Microwave Oven42 pg
Tech Sheet
- techsheet-w10420006-reva_W1042000656 pg
MyPros+ Max
Diagnose your Amana RC-10S/P73829-4M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (81)
CodeMeaning
afLow inlet air flow condition detected at installation.E0No errors present in the ice maker.E1Ice maker errorE2Ice maker errorE3Ice maker errorE4Ice maker errorE5Ice maker errorf:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).F0 E7Control board recognized line voltage below 90 VAC.View all 81 error codes
F1H.Vf1 e1Primary control failure.F1 E4UIC (User Interface Control) fault detected.F1 E7ACU voltage input fault.F1E1Indicates a Cycle Control Unit (CCU) problem.F2H.Vf2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2 E2Upper dryer keypad is sensed pressed for 60 seconds (stuck key).F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2UI software error; UI cannot read EEPROM software.F3H.Vf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms)F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4H.VF4E1No voltage detected at the heater relayF4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5Touch Panel failure.F5 E1Lower dryer door circuit error.F5 E6Upper dryer door circuit error.F6H.VF6 E1Communication failure between ACU and UIC.F6E1Communication between the CCU and UI has not been detected (UI to CCU).F6E2Communication between the CCU and UI has not been detected (CCU to UI).F7 E6Lower dryer motor circuit error.F7 E7Upper dryer motor circuit error.F7 E8Lower dryer motor sense errorF7 E9Upper dryer motor sense errorf8 e1No voltage detected at the water valve relay (steam models only, only appears…FC E1Model/Serial number not programmed into control.FC E2Model/Serial number not matching between ACU and UIC.FC E3Wi-Fi connection fault.FC E4USB stick failure (USB full, not detected, or not accessible).FC E5Software uploaded from USB stick does not match the model number of the machine.FC E6Model setup export failureFC E7Model setup import failureFC E8Wi-Fi module not responding or not connected.FP E1Coin 1 circuit errorFP E2Coin 2 circuit errorFP E3Card reader communication error.l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (41)
- Component ActivationFrom Service Diagnostics Diagnostics Home screen, select 'Component Activation'
- Control Panel Deactivation (RCS10MP P1140412M / RCS10MPS P1324901M)["Open oven door, and close oven door.","Press TIME ENTRY pad.","Press 1, 3, 5, and 7 pad in…
- Customer-Focused Drying Mode Adjustment1
- Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
- Customer-Focused Dryness Level Adjustment1. Turn cycle selector knob to an automatic cycle. 2. From the Automatic Cycle Main Screen, press…
- Deactivating Control Panel (RCS10MP P1140412M, RCS10MPS P1324901M)["Open oven door and close oven door.","Press TIME ENTRY pad.","Press 1, 3, 5, and 7 pad in…
- diagnosticPress DELICATES keypad for one second while in any of the set-up codes 1 through 6 (or while dAS…
- Diagnostic Mode["Enter Setup Mode first.","While in any of the set-up codes 1 through 6 (or while dAS displays if…
- Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
- helpPress HEAVY DUTY keypad while in special pricing option step 2.XX (or while dAS displays if…
- Help Mode["Enter Setup Mode first.","While in special pricing option step 2.XX (or while dAS displays if…
- Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
- Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
- model_serial_number_menuEnter Help Mode first
- Model/Serial Number Menu["Enter Help Mode.","While on the S0 screen, press the HEAVY DUTY key.","Use NORMAL key to advance…
- Programming Mode["Open oven door.","Press and hold pad 1 for approximately 5 seconds.","Microwave beeps and P:O…
- Programming mode (RCS10 P1140411M)["Open oven door.","Press and hold pad 1 for approximately 15 seconds.","Signal sounds and display…
- Programming mode (RCS10MP P1140412M / RCS10MPS P1324901M)["Open oven door.","Press and hold pad 1 for approximately 15 seconds.","After 15 seconds, signal…
- Programming mode (RCS10MP, RCS10MPS, RCS10 P1140412M / P1324901M)["Open oven door.","Press and hold pad 1 for approximately 15 seconds.","After 15 seconds, signal…
- Programming mode (RFS9B, RCS10, RCS10MP, RCS10MPS, RFS10S, RFS12MPS, RFS12S - 2000/2002 models)["Open oven door.","Press and hold pad 1 for approximately 5 seconds.","After 5 seconds, signal…
- Programming mode (RFS9B, RCS10, RCS10MP, RCS10MPS, RFS10S, RFS12MPS, RFS12S P1324xxx/P1327xxx series)["Open oven door.","Press and hold pad 1 for approximately 5 seconds.","After 5 seconds, signal…
- Quick Diagnostic TestFrom Diagnostics Home screen, select 'Error Diagnostic', then select 'Quick Diagnostic Test'
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE/COMPLETE…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Diagnostics ModePress SW1 and SW2 simultaneously for 3 seconds
- setupPD Models
- Setup Mode["Stacked PD Models
- UI Component TestFrom Diagnostics Home screen, select 'Component Activation', then select 'UI Component Test'
- USB Menu["Enter Help Mode.","While on the USB screen, press the HEAVY DUTY key.","Use NORMAL key to advance…
- usb_menuEnter Help Mode first
- User Interface/Control System TestAfter activating Service Diagnostic Mode, press and release the 1st button used to activate Service…
- User Options Mode["Open oven door.","Press and hold pad 2 for approximately 5 seconds.","Microwave beeps and OP
- User Options mode (RCS10MP P1140412M / RCS10MPS P1324901M)["Open oven door.","Press and hold pad 1 for approximately 15 seconds.","Press hidden…
- User Options mode (RCS10MP P1140412M, RCS10MPS P1324901M)["Open oven door.","Press and hold pad 1 for approximately 15 seconds.","After 15 seconds, signal…
- User Options mode (RFS10SW2, RFS12SW2)["Open oven door.","Press and hold pad 2 for approximately 5 seconds.","After 5 seconds, signal…
- User Options mode (RFS9B, RCS10, RCS10MP, RCS10MPS, RFS10S, RFS12MPS, RFS12S - 2000/2002 models)["Open oven door.","Press and hold pad 2 for approximately 5 seconds.","After 5 seconds, signal…
- User Options mode (RFS9B, RCS10, RCS10MP, RCS10MPS, RFS10S, RFS12MPS, RFS12S, RFS10SW2, RFS12SW2 P1324xxx/P1327xxx series)["Open oven door.","Press and hold pad 2 for approximately 5 seconds.","After 5 seconds, signal…
- wi-fi_menuFrom the F0 screen in setup mode, press HEAVY DUTY keypad to enter Wi-Fi mode
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass