4 documents43 error codes8 service modes
Available documentation
Tech Sheet
- Tech Sheet - W1037157520 pg
- Tech Sheet - W10419696 - Rev A28 pg
- Commercial Microwave Technical Information10 pg
- Tech Sheet16 pg
MyPros+ Max
Diagnose your Amana RC-10B-DD/P73547-13M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (43)
CodeMeaning
:Flashing colon indicates a power failure has occurred.F0E1Load detected in drum during Clean Washer cycle.F0E2OversudsF0E4High temperature error during wash cycle.F0E5Off balance load detected.F1.E1Relay Control Board defective.F1E1Main relay open or shorted.F1E2MCU over- or under-voltage error.F2Touch panel failure.F2.H1Hood/light switch stuck.F2.H2Hood/light switch error.F2.Q1User interface board (UIB) is not reading keypad inputs.F3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T2FC (forced convection) thermistor failure.F3.T4Magnetron thermistor failure.F3E1Pressure sensor signal missing or out of range.F3E2Wash NTC (thermistor) open or shorted.F3E5Dry NTC faultF3E6Accelerometer error.F3HHumidity sensor failure.F4E1Wash heater relay error or no feedback signalF4E2Wash heater relay error.F5E2Door lock failure.F5E3Door unlock failure.F5E4Door not open error.F6MW relay failure (Relay 4903 on Relay Board).F6E1No communication from the HMI detected by ACU.F6E2No communication from the ACU detected by the HMI.F6E3No communication from the MCU detected by the ACU.View all 43 error codes
F7Power to magnetron interrupted.F7E10Motor disconnected error.F7E12MC/MCU overload.F7E2MC/MCU over temperature error or over current error/internal failure.F7E8MC/Motor over temperature error.F7E9Motor will not turn (locked rotor).F7EAMotor disconnected error (alternate hex display of F7E10).F7ECMC/MCU overload (alternate hex display of F7E12).F8E1Water inlet valve failure.F8E3Overflow condition detected.F9Relay Control Board communications error.F9.QTouch communication error.F9E1Long drain
Service modes (8)
- Fault/Error Code Display["Enter Service Diagnostic Mode
- Human-Machine Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- Quick Diagnostic Test["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Service Diagnostic Mode["Ensure washer is in standby mode (plugged in with all indicators off).","Wait 30 seconds after…
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- Test Mode (Touch Panel and Relay Control Board Tests)["1
- Touch Panel and PCBA Self-Diagnostic Test Mode["1
- Touch Panel Test Mode["1
Full entry steps, exit procedures, and test sequences are available in Max.