Model reference
Amana RC-6PB/P73860-2M
Microwave
6 documents49 error codes17 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10340328 - Rev A64 pg
Service Manual
- Consumer Services Technical Education Group Presents KM-30 Microwave Oven Hood Combination54 pg
- Job Aid - Whirlpool Microwave Oven Hood Combination54 pg
Tech Tip
- Instruction Sheet2 pg
- Instruction Sheet W11420067 - Rev A1 pg
Installation Guide
- Installation Instructions7 pg
MyPros+ Max
Diagnose your Amana RC-6PB/P73860-2M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (49)
CodeMeaning
afLow inlet air flow condition detected at installation.E0No errors, functioning ice maker.E1No coolingE2Motor lost positionE3Heater time-outE4Dry cycleE5Ice maker thermistor is badErUI Failure detected during humidity sensor test.f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).View all 49 error codes
f1 e1Primary control failure.F1E1Primary control failure.F2Touch panel failure.f2 e1Stuck button or user interface mismatch (keypad/user interface failure)F2E1Stuck button or user interface mismatch (keypad/user interface failure)f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is openf3 e7Moisture sensor strip has shortedF3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF3HHumidity sensor failure.F6Microwave relay failure.f8 e1No voltage detected at the water valve relay (steam models only)F8E1No voltage detected at the water valve relay (steam models only)l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (17)
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
- Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostics Mode["Ensure refrigerator is not in lockout mode.","Press SW1 and SW2 simultaneously for 3…
- Touch Panel and Electronic Control Self-Diagnostic Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass