Model reference
Amana RR-910/P75413-3M
Microwave
8 documents77 error codes30 service modes
Available documentation
Tech Sheet
- Tech sheet20 pg
- Tech Sheet - W10492441 - Rev A32 pg
- Tech Sheet - W10340328 - Rev A64 pg
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet - W10403269 - Rev A52 pg
Service Manual
- servicemanual w10881701 l 9164 pg
- Job Aid - 4322536A (G-20)76 pg
Installation Guide
- Installation Instructions72 pg
MyPros+ Max
Diagnose your Amana RR-910/P75413-3M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (77)
CodeMeaning
AFRestricted airflow detected that may affect dryer performance.d13Coin 2 errord16Generation 2 debit card reader errord5Coin 1 errord9Low voltage detection errorE1 E5Oven user interface failure.F01Washer CCU errorF01 (dryer)Dryer motor control circuit errorF03Accelerometer failureF04Accelerometer failureF1No displayf1 e1Primary control failure.F11MCU (Motor Control Unit) errorF1E1Primary control failure.F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F1E5ACU parameter file missing.F2 E0Keypad disconnected.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F20No water detected entering washerF21Long drainF22Door lock errorF22 (dryer)Dryer exhaust thermistor open errorF23 (dryer)Dryer exhaust thermistor shorted errorF24Water temperature sensor errorF25Tachometer errorF26Door switch errorF27Overflow conditionF28Communication failure between washer CCU and MCU.F29Door unlock errorF2E1Stuck button or user interface mismatch (keypad/user interface failure)View all 77 error codes
F2E2User Interface software errorF2E3User Interface and ACU model ID parameter mismatch caused by replacement with…F2E4UI software errorF2E5UI software errorF3 E0Oven sensor (humidity sensor 1600 or oven cavity sensor) open or shorted.f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.F3 E4Microwave Oven Humidity Sensor Error.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F31Overheating of motorF33Pump disconnectedF34Load detected in washer during washer cleanout cycle.F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4 E1Main oven sensor open or shorted.f4 e4Low line voltage detected.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E2No voltage detected at heater relay 2 (electric models only), indicating a…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F4E5Temperature threshold of the dryer has been exceeded, usually indicating poor…F5 E0Door and latch switch do not agree.F5 E1Latch not operating.F6 E0Oven user interfaceF6 E1Over temperature during operation/self-clean.F6 E5No cavity size command.F6 E6Oven appliance manager 1 (upper, single)F6 E8Lost communications with Microwave Oven Appliance Manager.F6E1Communication errorF6E2Communication errorF6E3Communication errorF70Communication failure between washer CCU and UIC (User Interface Control).F70 (dryer)Communication failure from dryer CCU to UICF71 (dryer)Communication failure from UIC to dryer CCUF73UIC microprocessor errorF74UIC EEPROM errorf8 e1No voltage detected at the water valve relay (steam models only)F8E1No voltage detected at the water valve relay (steam models only)L2Low L2 voltage (less than 50V) detected at the CCU.Microwave Oven Inverter ErrorMicrowave oven inverter communication or operation error.pfPower failure occurred while the dryer was running.
Service modes (30)
- Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Diagnostics Mode 1Within 2 minutes of power up, press CANCEL > CANCEL > START
- Diagnostics Mode 2After 2 minutes of power up, press CANCEL > CANCEL > START
- Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
- Help Mode (dAS Mode)["Open the service door or insert a manual diagnostic card.","The message dAS will appear in the…
- Help Mode (PD Models)["Open the service door.","Press EXTRA RINSE washer key pad until display reads 2.XX.","Press…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
- P-01 Cancel Cycle, Reset Errors, and Clear Escrow["Enter Service Diagnostic Test Mode.","Display shows P-01.","Press START to clear active error…
- P-02 Cycle Credit["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-02 is…
- P-03 Quick Overview Test["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-03 is…
- P-04 Manual Overview Test["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-04 is…
- P-05 Button Test["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-05 is…
- P-06 Drain and Spin["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-06 is…
- P-07 UI Diagnostics["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-07 is…
- P-08 Clean Washer Cycle["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-08 is…
- P-10 Dryer Diagnostic Cycle["Enter Service Diagnostic Test Mode.","Press EXTRA RINSE washer key pad until P-10 is…
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostic Test Mode["Enter service mode per Control Set-Up Procedures (insert service switch key and turn…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate the…
- Set-Up Mode["PD/PN/PR Models
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass