mypros+
Model reference

Amana RV-10/P74582-1M

Microwave

8 documents67 error codes23 service modes

Available documentation

Tech Sheet

  • Tech Sheet W11415595 RevB4 pg
    Covers this model
  • Tech sheet60 pg
    Covers this model
  • Tech Sheet - W11087920 - Rev A60 pg
    Covers this model
  • Tech Sheet whirlpool dryer W10606148 Rev C60 pg
    Covers this model
  • tech sheet w11421232 reva60 pg
    Covers this model
  • Tech Sheet - W10403269 - Rev A52 pg
    Covers this model

Service Manual

  • ADC AD-200 ServiceManual-NonTilt-1993-thru-1998 PastProduction OPL82 pg
    Covers this model
  • servicemanual w10881701 l 9164 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RV-10/P74582-1M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (67)

CodeMeaning
AFRestricted airflow detected that may affect dryer performance.doorDoor switch circuit is opendrnDrain pump system problemdSFLFault detected in the microprocessor temperature sensing circuitF0E1Load detected in drum during Clean Washer cycle.F0E2Oversuds condition detectedF0E3Overload conditionF0E4Spin limited by water temperatureF0E5Off balance load condition detected.f1 e1Primary control failure.F1E1Primary control failure.F1E2Motor control section of the main control has faulted.F1E3Incorrect controller installed (electric models only); ACU or UI part number…F1E4Main relay open or shorted.F1E5ACU parameter file missing; parameter memory invalid.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch (keypad/user interface failure)F2E2User Interface software errorF2E3UI and ACU model ID parameter mismatch caused by replacement of either UI or…F2E4UI software errorF2E5UI software errorf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open (temperature below 18°F / >245k ohms) or shorted…F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…
View all 67 error codes

Service modes (23)

  • Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
  • Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRY LEVEL button for…
  • Diagnostic / Self-Diagnostic Test Mode["Plug in microwave oven or reconnect power.","In idle mode, close the door, turn off hood light…
  • Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
  • Fault Code Display / Clearing["Enter Service Diagnostic Mode.","If saved fault code exists, it will be flashing in the display…
  • Fault Code Display and ClearingFrom Service Diagnostic Mode, press and release the 3rd button to advance through saved fault codes
  • Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • Key Activation and Encoder TestFrom Service Diagnostic Mode, press and release the 1st button used to activate Service Diagnostic…
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
  • Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
  • Service Calibration["Enter Service Test Mode.","Select function number 052 using Soil Level/Temp buttons or cycle…
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
  • Service Diagnostic Mode (Alternate Method)1
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Service Diagnostics (Automated Test Cycle)["Enter Service Test Mode.","Select function number 051 using Soil Level/Temp buttons or cycle…
  • Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
  • Service Test Mode (Load Control)["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
  • User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass