Model reference
Amana RV-10/P74582-1M
Microwave
8 documents67 error codes23 service modes
Available documentation
Tech Sheet
- Tech Sheet W11415595 RevB4 pg
- Tech sheet60 pg
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet whirlpool dryer W10606148 Rev C60 pg
- tech sheet w11421232 reva60 pg
- Tech Sheet - W10403269 - Rev A52 pg
Service Manual
- ADC AD-200 ServiceManual-NonTilt-1993-thru-1998 PastProduction OPL82 pg
- servicemanual w10881701 l 9164 pg
MyPros+ Max
Diagnose your Amana RV-10/P74582-1M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (67)
CodeMeaning
AFRestricted airflow detected that may affect dryer performance.doorDoor switch circuit is opendrnDrain pump system problemdSFLFault detected in the microprocessor temperature sensing circuitF0E1Load detected in drum during Clean Washer cycle.F0E2Oversuds condition detectedF0E3Overload conditionF0E4Spin limited by water temperatureF0E5Off balance load condition detected.f1 e1Primary control failure.F1E1Primary control failure.F1E2Motor control section of the main control has faulted.F1E3Incorrect controller installed (electric models only); ACU or UI part number…F1E4Main relay open or shorted.F1E5ACU parameter file missing; parameter memory invalid.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch (keypad/user interface failure)F2E2User Interface software errorF2E3UI and ACU model ID parameter mismatch caused by replacement of either UI or…F2E4UI software errorF2E5UI software errorf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open (temperature below 18°F / >245k ohms) or shorted…F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…View all 67 error codes
F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedf4 e4Low line voltage detected.F4E1Heater 1 failure or connector problem; no voltage detected at the heater relay.F4E2Heater 2 failure or connector problem (electric models only); no voltage…F4E3Restricted airflow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the ACU (electric models only).F4E5High limit exceeded; temperature threshold of the dryer has been exceeded…F5E1Lid switch faultF5E2Lid lock will not lock or lid lock failure.F5E3Lid lock will not unlock.F5E4Lid not opened between cyclesF6E1Communication errorF6E2Communication errorF6E3Communication errorF7E0Loss of powerF7E1Loss of power during spinF7E2Motor drive module failureF7E3Basket engaged during washF7E4Basket re-engagement failureF7E5Shifter failure.F7E6Motor circuit openF7E7Motor unable to meet target RPM.F7E8Motor over temperatureF7E9Locked rotorF8E1No voltage detected at the water valve relay (steam models only)F8E3Overflow or flood conditionF8E6Water hazardF9E1Drain pump system problemF9E2Drain pump system problemFCE1WIFI Module has not responded for a specified amount of time; communications…FILLNormal idle/ready state display indicating the dryer is ready to accept a cycle…HotPossible overheating conditionL2Low L2 voltage (less than 30V) detected at the CCU.LFLong fillpfPower failure occurred while the dryer was running.SEFLRotational sensor circuit failure
Service modes (23)
- Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRY LEVEL button for…
- Diagnostic / Self-Diagnostic Test Mode["Plug in microwave oven or reconnect power.","In idle mode, close the door, turn off hood light…
- Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
- Fault Code Display / Clearing["Enter Service Diagnostic Mode.","If saved fault code exists, it will be flashing in the display…
- Fault Code Display and ClearingFrom Service Diagnostic Mode, press and release the 3rd button to advance through saved fault codes
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Key Activation and Encoder TestFrom Service Diagnostic Mode, press and release the 1st button used to activate Service Diagnostic…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Service Calibration["Enter Service Test Mode.","Select function number 052 using Soil Level/Temp buttons or cycle…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostic Mode (Alternate Method)1
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Diagnostics (Automated Test Cycle)["Enter Service Test Mode.","Select function number 051 using Soil Level/Temp buttons or cycle…
- Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Service Test Mode (Load Control)["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands