CodeMeaning
1 flashStand-by mode, waiting for call for heat (no fault)1 flash/secWeak pilot signal on last call for heat.2 flashPressure switch not working3 flashPressure switch or blower temperature switch not working4 flashExcessive tank temperature5 flashUndesired/false pilot flame present when pilot valve is not open.6-1 flashFailed to light pilot6-2 flashPressure switch or blower temperature switch opened during burner operation6-3 flashPilot flame extinguished during run6-4 flashUndesired/false pilot flame sensed out of sequence7 flashSimulated resistive device fault detected8-1 flashSimulated resistive device out of specification (resistance below 3,000 ohms).8-2 flashTemperature sensor fault8-3 flashGas valve electronics fault detected.8-4 flashGas valve fault detected.HeartbeatThermostat calling for heat (no fault)No LEDNo electrical power to the gas control.Related Bradford White water heater models