Model reference
Bradford White RG2PDV50H(N,X)
Water Heater
1 document17 error codes
Available documentation
Service Manual
- PDV Series Power Direct Vent Gas Water Heaters Service Manual40 pg
MyPros+ Max
Diagnose your Bradford White RG2PDV50H(N,X).
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (17)
CodeMeaning
1 short flash every 4 secondsStand-by mode, waiting for call for heat (no fault)1 short flash per secondWeak pilot signal detected on last call for heat.2 flashPressure switch not working3 flashPressure switch or blower temperature switch not working4 flashExcessive tank temperature detected5 flashUndesired/false pilot flame sensed when pilot valve is not open.6-1 flashFailed to light pilot6-2 flashPressure switch or blower temperature switch opened during burner operation6-3 flashPilot flame extinguished during operation6-4 flashUndesired/false pilot flame sensed out of sequence7 flashFlammable vapor sensor fault detected8-1 flashFlammable vapor sensor out of specification8-2 flashTemperature sensor fault8-3 flashGas valve electronics fault detected8-4 flashGas valve fault detectedHeartbeat (alternates bright/dim)Thermostat calling for heat (no fault)No LEDNo electrical power to the gas controlRelated Bradford White water heater models