Model reference
GE DCVH515
Dryer
7 documents10 error codes13 service modes
Available documentation
Service Manual
- Owner's Manual Dryers24 pg
- GE Dryer DBVH512 DCVH515 DHDVH52 Technical Service Guide50 pg
- GE Dryer Technical Service Guide50 pg
- GE dryer mini manual2 pg
- GE Dryer DBVH512 Mini Manual2 pg
- Dryers Owner's Manual24 pg
Other
- Pedestal 49 9023312 pg
MyPros+ Max
Diagnose your GE DCVH515.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (10)
CodeMeaning
E00No error detected.E01EEPROM failure (critical failure).E02Inlet thermistor short circuit.E03Outlet thermistor short circuit.E04Inlet thermistor open circuit.E05Outlet thermistor open circuit.E60Door switch malfunction.E61L2 and N incorrectly wired (AC input too high)E80Invalid UI model on control board.E81Invalid power model on control board.Service modes (13)
- Control Board Programming (Replacement)["Reconnect power to the dryer (display shows '---' indicating no model selected).","Rotate cycle…
- Service Test Mode["Disconnect power for 30 seconds.","Reconnect power.","Within 30 seconds of reconnecting power…
- t01 - Model ID["Enter Service Test Mode (displays t01).","Press Start/Pause to display current UI model…
- t02 - Error Codes["Enter Service Test Mode.","Navigate to t02.","Press Start/Pause to display most recent error…
- t03 - Software ID["Enter Service Test Mode.","Navigate to t03.","Press Start/Pause to display software revision…
- t04 - Program Non-volatile Memory Test["Enter Service Test Mode.","Navigate to t04.","Press Start/Pause to run test."]
- t05 - User Interface (LED Test)["Enter Service Test Mode.","Navigate to t05.","Press Start/Pause to turn on all LEDs and 7-segment…
- t05 - User Interface Test["Enter Service Test Mode.","Rotate knob to t05.","Press Start/Pause to enter."]
- t06 - Keys Continuity["Enter Service Test Mode.","Navigate to t06.","Press Start/Pause
- t07 - Outlet Thermistor Test["Enter Service Test Mode.","Navigate to t07.","Press Start/Pause
- t08 - Inlet Thermistor Test["Enter Service Test Mode.","Navigate to t08.","Press Start/Pause
- t09 - Moisture Sensor Test["Enter Service Test Mode.","Navigate to t09.","Press Start/Pause
- t10 - Exhaust Detection Test["Enter Service Test Mode.","Navigate to t10.","Press Start/Pause
Full entry steps, exit procedures, and test sequences are available in Max.