mypros+
Model reference

Jenn-Air JDS9865BDP

Range

12 documents35 error codes30 service modes

Available documentation

Service Manual

  • Maytag Heritage Wiring Diagrams _ Fault Codes MC 1124 pg
    Covers this model
  • Failure Codes and Wiring Diagrams for Maytag Heritage Gas & Electric Ranges124 pg
    Covers this model
  • FAILURE CODES AND WIRING DIAGRAMS for MAYTAG HERITAGE GAS & ELECTRIC RANGES124 pg
    Covers this model

Bulletin

  • Technical Bulletin - TDC-0093-B-French Wiring Diagram Change5 pg
    Covers this model
  • TechnicalBulletin-TDC-0093-B5 pg
    Covers this model
  • Technical Bulletin - TDC-0093-B-French Wiring Diagram Change5 pg
    Covers this model
  • Technical Bulletin - Wiring Diagram Change5 pg
    Covers this model

Service Flash

  • Service Pointer - 8178755 (Two Burner Cartridge)2 pg
    Covers this model
  • Service Update First HALF—200994 pg
    Covers this model

Installation Guide

  • Installation Instructions18 pg
    Covers this model
  • Installation Instructions48 pg
    Covers this model

Other

  • 81787551 pg
    Covers this model
MyPros+ Max

Diagnose your Jenn-Air JDS9865BDP.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (35)

CodeMeaning
1c1cShorted key detected on the control circuit board keyboard.1c2cKeyboard tail disconnected or keyboard loop has improper value.1c31Cancel key circuit problem (cancel key improper value) on upper/single oven…1c32Cancel key circuit problem (cancel key improper value) on lower oven cavity.1c4cPower micro communication failure (CRC invalid).1c6cEEPROM error1c7cControl not calibrated1c81Cook profile corrupted in EEPROM for upper/single oven cavity (CRC invalid).1c82Cook profile corrupted in EEPROM for lower oven cavity (CRC invalid).1d11Runaway temperature (650°F) detected with door unlocked on upper/single oven…1d12Runaway temperature (650°F) detected with door unlocked on lower oven cavity.1d21Runaway temperature (950°F) detected with door locked on upper/single oven…1d22Runaway temperature (950°F) detected with door locked on lower oven cavity.3d11Temperature sensor failure (open) on upper/single oven cavity3d12Temperature sensor failure (open) on lower oven cavity3d21Temperature sensor failure (short) on upper/single oven cavity3d22Temperature sensor failure (short) on lower oven cavity3d41Meat probe shorted3d51Meat probe not calibrated4d11Door switch position failure4d12Door switch position failure4d21No Reverse Airflow Fan rotation (no/low RPM) on upper/single oven cavity.4d22No Reverse Airflow Fan rotation (no/low RPM) on lower oven cavity.4d31Reverse Airflow Fan state error4d32Reverse Airflow Fan state error4d41High Reverse Airflow Fan rotation (high RPM) on upper/single oven cavity.4d42High Reverse Airflow Fan rotation (high RPM) on lower oven cavity.4d51Door switch circuit failure4d52Door switch circuit failure9d11Door latch will not lock on upper/single oven cavity
View all 35 error codes

Service modes (30)

  • Diagnostic Code Display Mode (H1 Controls)Press and hold AUTOSET pad for 3 seconds at power-up.
  • Diagnostic Code Display Mode (H1)Press and hold the Autoset pad for 3 seconds at power-up.
  • Diagnostic Code Display Mode (H2.5)Press and hold Upper Cancel and Autoset pads for 3 seconds
  • Diagnostic Code Display Mode (H3 Controls)Press and hold Upper Cancel and Timer for 3 to 5 seconds within 5 minutes of power up.
  • Diagnostic Code Display Mode (H3)Press and hold Upper Cancel and Timer for 3 to 5 seconds within 5 minutes of power up
  • Diagnostic Code Display Mode (M1/M2)Diagnostic Code Display Mode can only be started within 30 seconds when powering up the control.
  • Diagnostic Code Display Mode (NSC Controls)Press and hold the More + pad for 3 to 5 seconds when powering up the unit (within 60 seconds of…
  • Diagnostic Code Display Mode (NSC)Press and hold More + pad for 3 to 5 seconds within 60 seconds of powering up the unit. Cycle…
  • Faults Access (EOC III Controls)1
  • Faults Access (EOC III)1
  • One-Watt Standby Mode (NSC Controls)Press and hold Cancel and Less
  • One-Watt Standby Mode (NSC)Press and hold Cancel and Less
  • Quick Test Mode (EOC III Controls)1
  • Quick Test Mode (EOC III)1
  • Quick Test Mode (H1 Controls - Convection Model)1
  • Quick Test Mode (H1 Controls - Non-Convection Model)1
  • Quick Test Mode (H1 Convection Model)1. Press and hold Cancel and Broil pads for 3 seconds. 2. Release both pads. 3. Press pads
  • Quick Test Mode (H1 Non-Convection Model)1. Press and hold Cancel and Toast pads for 3 seconds. 2. Release both pads. 3. Press pads
  • Quick Test Mode (H2/H2.5 Control)1. Press and hold Cancel and Broil pads for 3 to 5 seconds. 2. Release both pads. 3. Press pads
  • Quick Test Mode (H2/H2.5 Controls)1
  • Quick Test Mode (H3 Control)1. Press and hold Upper Cancel and Broil pads for 3 seconds. 2. Release both pads. 3. Press pads
  • Quick Test Mode (H3 Controls)1
  • Quick Test Mode (M1/M2 Control)1. Press and hold Cancel and Broil pads for 3 seconds. 2. Release both pads. 3. Press pads
  • Quick Test Mode (M1/M2 Controls)1
  • Quick Test Mode (NSC Non-Self Clean Controls)1
  • Quick Test Mode (NSC Non-Self Cleaning Control)1. Press and hold Cancel and Broil pads for 3 to 5 seconds within 5 minutes of power-up. 2. Release…
  • Service Mode (EOC III Controls)1
  • Service Mode (EOC III)1
  • Test Mode (UH Control)1
  • Test Mode (UH Controls)1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass