KitchenAid KFES530ESS2

Range

3 documents42 error codes29 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10694022 - Rev A8 pg
    Covers this model

Service Manual

  • SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
    Covers this model
  • Technical Manual - Cooking Surface Temperature Limits12 pg
    Covers this model
MyPros+ Max

Diagnose your KitchenAid KFES530ESS2.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (42)

CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1-E0EEPROM communication error on the oven control.F1-E0 (cooktop)EEPROM communication error on the cooktop control.F1-E5PCB thermistor open or shorted on the oven control.F1-E7WIDE queue full on the oven control.F1-E7 (cooktop)PCB thermistor/sensor open or shorted on the cooktop control.F1-E9Keypad disconnected from the oven control.F1-E9 (cooktop)WIDE queue full on the cooktop control.F1E0Internal board failure (LCC/LCX control).F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2-E0Stuck key detected on the user interface keypad.F2-E1Stuck key detected on the user interface keypad.F2-E1 (cooktop)Stuck key detected on the cooktop control keypad.F2-E2Cancel key error on the user interface keypad.F2E0Shorted key (LCC/LCX control).F2E1Stuck KeypadF3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer temperature sensor open or shorted.F3E0Oven sensor opened (LCC/LCX control)F3E1Oven sensor shorted (LCC/LCX control).F3E2Bake/Broil range over temperature (LCC/LCX control).F3E3Clean range over temperature (LCC/LCX control).F5-E0Door position and door switch do not agree.F5E0Door and door position switch do not agree during Clean mode (Maxwell/MRC…F5E1Door latch not operating during Clean mode (LCC/LCX control).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6-E0 (cooktop)Right cooktop communication error.F6-E1Over temperature condition during cook cycle.
View all 42 error codes

Service modes (29)

  • Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
  • Auto Test (Maxwell Oven Control)["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Press up arrow, '+' key, or '3' key to scroll…
  • Auto Test (Maxwell/MRC Controls)1
  • Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
  • CONTROL RESET["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 6
  • Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
  • Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
  • Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
  • Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
  • Diagnostics Mode (Cooktop EGO Controls)["Ensure both cooktop (EGO) controls are OFF (idle mode)","Touch OFF > OFF > ON for the selected…
  • Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
  • Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
  • Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
  • Diagnostics Mode (Maxwell Oven Control)["Press CANCEL","Press CANCEL","Press START","Display shows 'TEST ON' with cavity temperature and…
  • Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
  • Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
  • DISPLAY["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 5
  • ENG MODE["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 2
  • EXTERNAL FAULTS["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 8
  • FAULTS["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 7
  • RELAY USAGE["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 9
  • Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
  • Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
  • Temperature Adjustment (Maxwell Controls)["Press OPTIONS until 'Temp Calib' is displayed","Press '3' or '6' on numeric keypads (or up/down…
  • TEST MODE["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 3
  • TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
  • TEST ON (Relay Checks)["Enter Diagnostics Mode (CANCEL > CANCEL > START)","At 'TEST ON' display, press the key listed for…
  • USAGE["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 1
  • VERSION["Enter Diagnostics Mode (CANCEL > CANCEL > START)","Scroll to service mode step 4

Full entry steps, exit procedures, and test sequences are available in Max.