Model reference
KitchenAid KGST307HWH8
Range
9 documents43 error codes5 service modes
Available documentation
Tech Sheet
- Kitchenaid Range KGST307HWH2 KGST307HWH3 KGST307HWH4 KGST307HWH5 Tech Sheet 97536218 pg
- Whirlpool Oven YKGRT607HS6 Tech Sheet8 pg
- Wiring Sheet - 97543721 pg
- TECH SHEET - 9754241 - Rev A8 pg
- Tech Sheet 9754241 KGRT607HBS6 KA Range8 pg
Installation Guide
- Instruction Sheet2 pg
- Installation Instructions12 pg
- Instruction Sheet1 pg
Other
- 431716993 pg
MyPros+ Max
Diagnose your KitchenAid KGST307HWH8.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (43)
CodeMeaning
F0 E0No fault found.F1 E2Lost communication with power board.F1 E3Configuration jumper change; freestand, electric switches or P3 pins 1 to 5…F1 E4Oven sensor not calibrated.F1 E5Meat probe not calibrated.F1 E6Display board EPROM access failure.F1 E7Power board EPROM access failure.F1 E8Improper keypad feedback (power board supply lift).F1 E9Unstable keyboard gain.F1 EAExceeded stack warning level.F1E0EEPROM read fault (silent fault, not displayed).F1E1EEPROM checksum does not match at start key (silent fault, not displayed).F1E3Configuration jumper change; freestand, electric switches or P9 pins 6 to 7…F1E4Q8 shorted.F1E9Stack overflow, highest priority.F2 E0User is cleaning too long or keypad is disconnected.F2 E1Cancel key invalid.F2 E3Key held down too long or keyboard short or spill on switch surface.F2E0Cancel key level too low (open).F2E2Cancel key loop test failed.F2E3Key held down too long or keyboard short.F2E4Keys unsettled probably due to noise.F3 E0Oven sensor open circuit.F3 E3Shorted oven sensor.F3 E4Oven temperature too high (runaway condition).F3E0Oven sensor open.F3E1Shorted oven sensor.F3E2Oven temp too high (runaway).F4 E0Meat probe shorted (less than 1500 ohms).F4E1Meat probe shorted (less than 1500 ohms).View all 43 error codes
F5 E1Self clean latch not locking.F5 E5Self clean temperature not achieved after 30 minutes.F5 E7Door unlocked but will not unlatch after clean cycle.F5E1Self clean latch lock make after 30 seconds.F5E3Loss of 120 VAC across L1 to Ground or Q19 circuit error.F5E5Self clean temperature not satisfied after 30 minutes.F5E6Door locked somehow with door open.F5E7Door unlocked somehow and will not unlatch.F6E0Ambient (console bi-metal) sensor opened (too hot).F7 E0Invalid latch switch reading.F7 E1Invalid door switch reading.F7E0Input switches won't follow their strobe level (shorted to ground).PFPower failure indication (not a failure mode).
Service modes (5)
- End of Service Test Sequence (Convection Units)["Connect unit to power, set power ON and wait until CONTROL LOCK clears and display shows PF…
- End of Service Test Sequence (Non-Convection Units)["Connect unit to power, set power ON and wait until CONTROL LOCK clears and display shows PF…
- F1 E3 Configuration Reset (Convection Units)["Ensure harness to P1 connector is correctly installed per wiring diagram.","Power off and wait 5…
- F1 E3 Configuration Reset (Non-Convection Units)["Ensure harness to P1 connector is correctly installed per wiring diagram.","Power off and wait 5…
- F1E3 Configuration Reconfiguration["Step 1: Make sure harness to P1 connector is correct per wiring diagram.","Step 2: Power down and…
Full entry steps, exit procedures, and test sequences are available in Max.
Related KitchenAid range models
78,000+ service manuals · 160,000+ error codes · 55+ brands