Model reference
Maytag MDG120
Dryer
1 document27 error codes8 service modes
Available documentation
Service Manual
- Phase 7.2.2 Non-coin User's Manual (S.a.f.e.)88 pg
MyPros+ Max
Diagnose your Maytag MDG120.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (27)
CodeMeaning
AXIAL PROBE FAULTProblem with the axial temperature sensor circuit.BURNER CONTROL FAULTGas return valve signal did not turn on before DSI purge time expired or turned…BURNER HIGH-LIMIT FAULTBurner high-limit switch opened during cycle while heat was on.BURNER PURGE FAULTControl detected presence of gas return signal before sending the heat signal…CHECK CONTROL BOARD FUSE #2Main fuse (fuse 2) on the Phase 7 control board has opened; 24V control power…CLEAN LINTLint cleaning frequency timer has expired; lint drawer must be opened for at…DISCONNECTED WATER VALVES.A.F.EEE PROM FAULT ###Error in memory location; the ### indicates the specific location of the fault.EXHAUST HIGH TEMP FAULTOverheating detected; temperature sensor input showed steady gradual increase…EXHAUST HIGH-LIMIT FAULTBasket (tumbler) safety over-temperature switch has opened.EXHAUST PROBE FAULTProblem with the exhaust temperature sensor circuit.FLAME FAULTGas valve return signal lost after DSI proof time during normal operation…IGNITION FAULTGas valve return signal was lost during DSI proof time and retry count has been…LINT ACCESS OPENLint drawer is open and needs to be closed.LOW VOLTAGE FAULTPower has dropped below operating values and the system will shutdown.MAIN DOOR OPENEDMain door is open when it should be closed.MODEL ERROR, ENTER CORRECT MODELController detected input signals (sail switch, gas valve) that do not match…OPEN THERMISTOR PROBES.A.F.EROTATION SENSOR FAULTTime between rotational sensor pulses exceeded 10 seconds, indicating basket…S.A.F.E. SYSTEM ACTIVATEDControl has detected a fire in the basket (tumbler) and is currently…S.A.F.E. SYSTEM DISABLED READYA fault has been detected in the S.A.F.ES.A.F.E. SYSTEM WAS ACTIVATEDControl detected a fire and has completed extinguishing the flame.SAIL SWITCH CLOSED FAULTSail switch is in the closed position at startup or restart; the controller…SAIL SWITCH OPEN FAULTSail switch did not close within 8 seconds of starting/restarting, or opened…SHORTED THERMISTOR PROBES.A.F.ESHORTED WATER VALVES.A.F.EWATER NOT CONNECTEDNo water pressure at the S.A.F.EService modes (8)
- Basket RPM DisplayPress and hold the DOWN ARROW key while a cycle is in progress and the basket is rotating.
- CPU Board Voltage DisplayPress and hold the DOWN ARROW key when no cycle is in progress.
- Cycle PreviewFor A-F cycles
- Default Factory Settings Reset1. Enter Programming Mode (STOP/CLEAR + UP ARROW). 2. Navigate to menu item 4
- Live Basket Temperature DisplayPress and hold the UP ARROW key during a cycle or at any time.
- Programming Mode1
- S.A.F.E. System Diagnostic Display1
- S.A.F.E. System Valve Check1
Full entry steps, exit procedures, and test sequences are available in Max.