CodeMeaning
F0 E0No fault found.F1Shorted keypad (4-digit displayF1 E2Lost communication with power board.F1 E3Configuration jumper change; freestand, electric switches or P3 pins 1 to 5…F1 E4Oven sensor not calibrated.F1 E5Meat probe not calibrated.F1 E6Display board EPROM access failure.F1 E7Power board EPROM access failure.F1 E8Improper keypad feedback from power board supply lift.F1 E9Unstable keyboard gain.F1 EAExceeded stack warning level.F2Shorted keypad (4-digit displayF2 E0User is cleaning too long or keypad is disconnected.F2 E1Cancel key invalid.F2 E3Key held down too long or keyboard short or spill on switch surface.F3Oven temperature sensor faultF3 E0Oven sensor open circuit.F3 E1Oven temperature sensor shorted.F3 E2Oven over temperature limits.F3 E3Shorted oven sensor.F3 E4Oven temperature too high (runaway condition).F4 E0Meat probe shorted (less than 1500 ohms).F5Multiple possible failures depending on sub-codeF5 E0Analog to Digital failure or Safety Flip FlopF5 E1Self clean latch not locking.F5 E2Door Lock Error.F5 E5Self clean temperature not achieved after 30 minutes.F5 E7Door unlocked but will not unlatch during clean cycle.F7 E0Invalid latch switch reading.F7 E1Invalid door switch reading.View all 31 error codes
Service modes (3)
- End of Service Test Sequence (Convection Units)["Connect unit to power, set power ON and wait until CONTROL LOCK clears and display shows PF…
- End of Service Test Sequence (Non-Convection Units)["Connect unit to power, set power ON and wait until CONTROL LOCK clears and display shows PF…
- Temperature Adjustment (Calibration)Press and hold BAKE pad for five (5) seconds. Current offset, if any, is shown in 3-digit display…