7 documents36 error codes13 service modes
Available documentation
Tech Sheet
- Electric Wall Oven Technical Information10 pg
- wiringsheet-w10192629-revb-fr.pdf2 pg
- wiringsheet-w10192628.pdf2 pg
Service Manual
- Electric Wall Ovens Service Manual37 pg
- Service Manual - Electric Wall Ovens37 pg
Bulletin
- Technical Bulletin - Installation Dimension Correction1 pg
Installation Guide
- Installation Instructions16 pg
MyPros+ Max
Diagnose your Maytag MEW5527DDB16.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (36)
CodeMeaning
1c1cShorted key detected on control circuit board.1c2cKeyboard tail disconnected from control board.1c31Cancel key circuit problem (upper/single oven).1c32Cancel key circuit problem (lower oven).1c4cPower micro communication failure (UH control only).1c6cEEPROM error1c7cControl not calibrated1c81Cook profile corrupted in EEPROM (upper oven, UH control only).1c82Cook profile corrupted in EEPROM (lower oven, UH control only).1c8cCooking program error1d11Runaway temperature (650°F) detected with door unlocked (upper/single oven).1d12Runaway temperature (650°F) detected with door unlocked (lower oven).1d21Runaway temperature (950°F) detected with door locked (upper/single oven).1d22Runaway temperature (950°F) detected with door locked (lower oven).3d11Temperature sensor open (upper/single oven)3d12Temperature sensor open (lower oven)3d21Temperature sensor shorted (upper/single oven)3d22Temperature sensor shorted (lower oven)3d41Meat probe shorted3d51Meat probe not calibrated4d11Door switch position failure4d12Door switch position failure4d21No Reverse Airflow Fan rotation (no/low RPM) during cook or clean (upper/single…4d22No Reverse Airflow Fan rotation (no/low RPM) during cook or clean (lower oven…4d31Reverse Airflow Fan state error4d32Reverse Airflow Fan state error4d41High Reverse Airflow Fan rotation4d42High Reverse Airflow Fan rotation4d51Door switch circuit failure4d52Door switch circuit failureService modes (13)
- 24 Hour Clock TogglePress and hold Cancel and Favorite pads for 3 seconds.
- Child Lock OutPress and hold Cancel and Cook & Hold pads for 3 seconds
- Clock Display Toggle (On/Off)Press and hold Cancel and Clock pads for 3 seconds.
- Diagnostic Code Display (H1/H2 via Quick Test)Enter Quick Test mode, then press COOK & HOLD to display last diagnostic code, or press AUTOSET to…
- Diagnostic Code Display ModePress and hold the AUTOSET pad for 3 seconds at power-up
- Diagnostic Code Display Mode (H1/H2 Control)Press and hold the AUTOSET pad for 3 seconds at power-up
- Factory Default ResetPress and hold Cancel and Keep Warm pads for 3 seconds.
- Oven Temperature Adjustment1
- Quick Test ModePress and hold CANCEL and BROIL pads simultaneously for 3 seconds
- Quick Test Mode (H1/H2 Control)1
- Sabbath ModeHold CLOCK pad for 3 seconds to activate Sabbath mode
- Temperature Display Toggle (F/C)Press and hold Cancel and Bake pads for 3 seconds.
- Test Mode (UH1/UH2 Control)1