Model reference
Maytag 16025647
Range
2 documents27 error codes13 service modes
Available documentation
Tech Sheet
- Electric Freestanding Range⎯Technical Information9 pg
Service Manual
- Service Manual - Electric Freestanding Range36 pg
MyPros+ Max
Diagnose your Maytag 16025647.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (27)
CodeMeaning
1c1cShorted key1c2cKeyboard tail disconnected1c31Cancel key circuit problem1c32Cancel key circuit problem (cancel key improper value, second instance).1c6cEEPROM error1c7cControl not calibrated1c8cCooking program error1d11Runaway temperature (650°F) with door unlocked1d12Runaway oven temperature (650°F) detected with door unlocked (second instance)…1d21Runaway temperature (950°F) with door locked1d22Runaway oven temperature (950°F) detected with door locked (second instance)…3d11Sensor open3d12Oven temperature sensor open (second instance)3d21Sensor shorted3d22Oven temperature sensor shorted (second instance)4d11Door switch position failure4d12Door switch position failure (second instance)4d21No reverse airflow fan rotation (no or low RPM detected).4d31Reverse airflow fan is on when it should be off.4d51Door switch circuit failure4d52Door switch circuit failure (second instance)9d11Latch will not lock9d12Oven door latch will not lock (second instance)9d21Latch will not unlock9d22Oven door latch will not unlock (second instance)9d31Latch state unknown9d32Latch state unknownService modes (13)
- 24 Hour Clock TogglePress and hold Cancel and Delay pads for 3 seconds.
- Child Lock OutPress and hold Cancel and Cook & Hold pads for 3 seconds
- Clock Display Toggle (On/Off)Press and hold Cancel and Clock pads for 3 seconds.
- Diagnostic Code Display1
- Diagnostic Code Display (H1 Control)Press and hold AUTOSET pad for 3 seconds at power-up
- Diagnostic Code Display (M1/M2 Control)Press and hold Up Arrow pad and power up the unit simultaneously
- Factory Default ResetPress and hold Cancel and Keep Warm pads for 3 seconds.
- Oven Temperature Adjustment1
- Quick Test1
- Quick Test (H1 Control)1
- Quick Test (M1/M2 Control)1
- Sabbath ModeHold CLOCK button for 3 seconds to activate Sabbath mode.
- Temperature Display Toggle (°F/°C)Press and hold Cancel and Bake pads for 3 seconds.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax