Error codes (21)
CodeMeaning
1c1cShorted key detected on membrane keyboard.1c2cMembrane keyboard disconnected.1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error1c8cEEPROM CRC error1d11Unlocked runaway temperature1d21Locked runaway temperature3d11Temperature sensor open circuit.3d21Temperature sensor shorted.3d41Meat probe shorted.3d51Meat probe not calibrated.4d11Door switch not closed when locked.4d21No cooling fan rotation detected.4d31Cooling fan on when de-energized.4d41Cooling fan overspeed.4d51Door switch circuit fault.9d11Door latch will not lock.9d21Door latch will not unlock.9d31Door latch both locked and unlocked simultaneously.Service modes (8)
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- Demo Mode1
- Display Test1
- Faults Access1
- Quick Test1
- Service Mode1
- Software Versions Access1
Full entry steps, exit procedures, and test sequences are available in Max.