Model reference

Norcold N7X

Refrigerator

4 documents22 error codes8 service modes

Available documentation

Service Manual

  • Service Manual - Gas Electric Refrigerators60 pg
    Covers this model
  • Manuel d'entretien - Réfrigérateurs au gaz et à l'électricité60 pg
    Covers this model
  • Manual de servicio - Refrigeradores eléctricos y de gas60 pg
    Covers this model
  • Cooling Unit Replacement Service Kits36 pg
    Covers this model
MyPros+ Max

Diagnose your Norcold N7X.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (22)

CodeMeaning
AC HEAC heater faultAC rEAC heater relay on the main control board (power board) is stuck closed…dc HEDC heater faultdc rEDC heater relay (K1 on the DC Board) contacts are stuck closed (N7LX/N8LX…FL --A flame is sensed at the burner when there should be none present; gas valve is…HI dcDC input voltage to the refrigerator is too high (N7LX/N8LX models).Lo dcDC input voltage to the refrigerator is low; cooling is to continue (N7LX/N8LX…Lo dCDC input voltage to the refrigerator is too low; all modes are inhibited…Lo dc (alarm)DC input voltage to the refrigerator is too low; either GAS MODE or DC MODE…Lo dc (with alarm)DC supply voltage too low; gas mode and/or DC mode (3-way) inhibited…Lo dC (with alarm)DC supply voltage too low; all modes inhibited.no ACAC voltage is not available to the refrigerator (N7LX/N8LX models).no dtCommunications between the user interface (controls) and the main control board…no FLThe burner did not ignite or re-ignite; no flame sensed at burner when there…oP LIThis fault is within the refrigerator controls.Solid RedThe refrigerator tried to operate on the selected energy source(s) with no…srInternal control fault (short circuit) detected by main control board.Thermistor Fail (Amber blink off every 20 sec)Refrigerator operating on propane gas; thermistor detected as non-functioning…Thermistor Fail (Green blink off every 20 sec)Refrigerator operating on AC power; thermistor detected as non-functioning…Thermistor Fail (Snowflakes flash on/off)Thermistor detected as non-functioning; backup operating system controlling…Thermistor Fail (Temp setting flashes)Thermistor detected as non-functioning; backup operating system controlling…Thermistor FaultThe thermistor has been sensed as inoperable; temperature is being controlled…

Service modes (8)

  • Diagnostic Mode (N7LX and N8LX models)1
  • Diagnostic Mode (N7LX/N8LX models)Press and hold both the MODE and Temperature Adjustment buttons simultaneously for 5 seconds
  • Diagnostic Mode (N7LX/N8LX)Press and hold MODE and Temperature buttons simultaneously for 5 seconds
  • Erase Fault History (within Diagnostic Mode, Screen 6, N7LX/N8LX)1
  • Manual Gas Propane Mode Toggle (N7V/N8V)From Auto mode
  • Mode Change (N7V and N8V - Auto to Manual Gas)Touch and hold the Power ON/OFF button for between 20-23 seconds
  • Temperature Set Mode (N7V and N8V models)1
  • Temperature Setting Mode (N7V/N8V)Press and hold On/Off button

Full entry steps, exit procedures, and test sequences are available in Max.

Related Norcold refrigerator models

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started