Model reference
Sub-Zero I700TCI-RH
Refrigerator
6 documents32 error codes19 service modes
Available documentation
Service Manual
- Sub-Zero 700-2: Serials 1670316 to 2347395 — Service Manual165 pg
- Sub-Zero Original: Prior to Serial 1670316 — Service Manual49 pg
- Sub-Zero 700-3 Tall (3758412): After Serial 2377228 — Service Manual130 pg
Parts Manual
- Sub-Zero 700-2: Serials 1670316 to 2347395 — Parts Manual40 pg
- Sub-Zero Original: Serials 0 to 1670315 — Parts Manual30 pg
- Sub-Zero 700-3 Tall: After Serial 2377228 — Parts Manual44 pg
MyPros+ Max
Diagnose your Sub-Zero I700TCI-RH.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (32)
CodeMeaning
--Unit is in shutdown mode; all unit functions suspended except lights and door…-20Zone thermistor is unplugged or faulty (open circuit) in the indicated zone.-88Red wire of display cable is unhooked or faulty; top lights off and keys…05Refrigerator cabinet thermistor read open or shorted for 10+ seconds, or…06Refrigerator evaporator thermistor read open or shorted for 10+ seconds, or…07Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly…08Freezer evaporator thermistor read open or shorted for 10+ seconds, or…20Defrost under-heat with no voltage feedback through Gray/White wire at defrost…21Defrost overheat.22No voltage feedback through Gray/White wire at defrost start.23Defrost overheat with no voltage feedback through Gray/White wire at defrost…24Defrost under-heat.30Excessive icemaker water valve solenoid activation (exceeded 15 seconds).40Excessive freezer compressor run.50Excessive refrigerator compressor run.55Zone thermistor is shorted in the indicated zone.80High variable speed compressor differential pressure or low voltage supplied to…81High amperage draw at variable speed compressor (700TF/I-2V only).82VS compressor could not maintain lowest minimum speed at highest current draw…83Locked variable speed compressor rotor (700TF/I-2V only).84Short circuit at VS compressor controller output circuit (700TF/I-2V only).85VS compressor converter overheated and shut down VS compressor (700TF/I-2V…86Serial communication failure between VS compressor controller and electronic…87Speed information from electronic control board is out of specification…88Electronic control board not receiving status data in response to speed…E0Communication error between control board and control panel (base units only).E3Communication error between control board and control panel (base units only).ECExcessive compressor run with error codes registered in the electronic control…EECompartment or evaporator thermistor (or its wiring) is open, shorted, or has a…ICEFlashing ICE and SERVICE annunciators indicate water valve solenoid was…Service modes (19)
- Diagnostic ModeWith unit ON, press and hold either COLDER key, then press the UNIT ON/OFF key, then release both…
- Diagnostic Mode (Base Units)1
- Diagnostic Mode (Tall Units)1
- Manual Compartment Disable Mode (Tall Units only)1
- Manual Component Activation ModeWith unit ON, press and hold the desired zone COLDER key and the UNIT ON/OFF key for 10 seconds
- Manual Component Activation Mode (Tall Units only)1
- Manual Defrost Initiation["Turn OFF master power switch for 10 seconds.","Turn master power switch back ON.","Control will…
- Manual Freezer Evaporator DefrostPress and hold the ICE ON/OFF key for 5 seconds, then release.
- Manual Zone Disable ModeSwitch unit OFF using UNIT ON/OFF key
- Sabbath ModeSwitch unit OFF using UNIT ON/OFF key
- Set Mode (Temperature Adjustment)["Press ZONE key to activate set mode and display setpoint for each zone.","Press ZONE key until…
- Showroom ModeSwitch unit OFF using UNIT ON/OFF key
- Shutdown Mode["Attempt to set temperatures warmer than control limits."]
- Temperature Log Recall Mode - Compartment and Evaporator (Tall Units)1
- Temperature Log Recall Mode - Compartment Only (Tall Units)1
- Temperature Log Recall Mode (Compartment and Evaporator)With unit ON, enter Diagnostic Mode first
- Temperature Log Recall Mode (Compartment Only)With unit ON, press and hold the desired compartment WARMER key, then press the UNIT ON/OFF key…
- Temperature Units Selection ModeMust be performed within the first minute after switching the unit ON
- Temperature Units Selection Mode (Fahrenheit/Celsius)1
Full entry steps, exit procedures, and test sequences are available in Max.