Sub-Zero Refrigerator Error Code 55

Zone thermistor is shorted in the indicated zone.

Zone thermistor is shorted in the indicated zone.

First step from the service manual

Repair wiring or replace thermistor. Turn unit OFF at master power switch for 10 seconds, then back ON to clear error mode.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 55.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 55 means on a Sub-Zero refrigerator

Error code 55 on a Sub-Zero refrigerator indicates that the zone thermistor in the flagged zone has developed a short circuit condition. A thermistor is a temperature-sensing resistor whose electrical resistance changes predictably with temperature. In normal operation, the control board reads this resistance to determine the zone's temperature and regulate the cooling system accordingly. When the thermistor shorts, its resistance drops abnormally low, causing the board to receive a temperature reading that is either severely out of range or completely invalid. The control board interprets this as a fault and triggers error code 55.

The most common causes of a shorted thermistor include physical damage to the sensor body or its wiring harness, moisture intrusion into the connector, or a pinched wire that has allowed two conductors to make unintended contact. In some cases, the thermistor itself degrades internally and shorts without any external cause. The wiring harness between the sensor and the control board is also a frequent failure point, particularly at connector terminals where corrosion or mechanical stress can cause conductors to bridge.

Diagnosing this fault requires inspecting the wiring harness and connectors in the affected zone for signs of damage, pinching, or corrosion, and then measuring the thermistor's resistance at the sensor leads to confirm whether the component itself has failed or whether the fault lies in the wiring. After any repair, the unit must be powered off at the master switch for at least 10 seconds and then powered back on to allow the control board to exit error mode and resume normal operation.

Source: manufacturer service documentation.

Common causes of 55

  1. 01

    Failed zone thermistor

    Part replacement

    The thermistor sensor itself has shorted internally, which produces an abnormally low resistance reading. This can be confirmed by measuring resistance directly at the sensor leads and comparing the result to the expected value for the ambient temperature.

  2. 02

    Damaged wiring harness

    Part replacement

    A pinched, chafed, or cut wire in the harness between the thermistor and the control board can cause two conductors to contact each other, creating a short. Inspect the harness routing in the affected zone for visible damage or pinch points.

  3. 03

    Corroded or bridged connector terminals

    Wiring / connection

    Moisture intrusion into the wiring connector can cause corrosion that bridges adjacent terminals and creates a short circuit. Inspect all connectors in the zone's thermistor circuit for discoloration, corrosion, or moisture.

  4. 04

    Loose connector causing intermittent short

    Wiring / connection

    A partially seated connector can allow terminal pins to contact the connector housing or adjacent pins under vibration. Reseating and securing the connector may resolve the fault without replacing any components.

  5. 05

    Control board fault

    Part replacement

    In rare cases, the control board's thermistor input circuit may have failed in a way that mimics a shorted sensor. This is typically considered only after the thermistor and wiring have been tested and confirmed good.

See the test procedure for each cause

Frequently asked questions about 55

What does 55 mean on a Sub-Zero refrigerator?
Error code 55 means the zone thermistor in the indicated cooling zone has shorted. The thermistor is a temperature sensor that the control board relies on to regulate cooling. A short causes the board to receive an invalid signal, triggering this fault code. The refrigerator may not cool correctly in the affected zone until the issue is resolved.
Can I fix error code 55 myself on a Sub-Zero refrigerator?
Some aspects of this repair are DIY-accessible, such as inspecting the wiring harness, checking connectors for corrosion or loose seating, and reseating connections. Replacing the thermistor sensor itself is also a straightforward part swap for experienced DIYers. However, if the control board is involved or the wiring damage is extensive, professional service is recommended.
Will resetting my Sub-Zero refrigerator clear error code 55?
Turning the unit off at the master power switch for 10 seconds and then back on will clear the error mode, but this does not fix the underlying problem. If the thermistor is still shorted after the reset, the error code will return. The wiring or thermistor must be repaired or replaced before a reset will hold.
Is it safe to keep using my Sub-Zero refrigerator while error code 55 is active?
Continuing to run the unit with an active thermistor short means the control board cannot accurately read temperatures in the affected zone. This could result in inconsistent cooling or food safety concerns if the zone fails to maintain proper temperature. It is best to address the fault promptly rather than operating the refrigerator in a degraded state.
How much does it cost to repair error code 55 on a Sub-Zero refrigerator?
Repair costs vary depending on whether the fault is in the wiring, the thermistor, or the control board. A thermistor replacement is typically the least expensive scenario, with parts and labor often ranging from around $150 to $350. Wiring repairs and control board replacements will generally cost more, potentially ranging from $300 to $700 or higher depending on the extent of the damage and local labor rates.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass