Model reference
Thermador CIT36XKB
Cooktop
3 documents31 error codes9 service modes
Available documentation
Service Manual
- Thermador CIT36XKB EF BB BF 06 Cooktop Service Manual51 pg
- Error Codes and Service Programmes Full Surface Induction (FSI)48 pg
Wiring Diagram
- Thermador CIT36XKB_06 Cooktop Schematic1 pg
MyPros+ Max
Diagnose your Thermador CIT36XKB.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (31)
CodeMeaning
C0Communication error with the Touch Control due to defective LIN bus wiring…C1Communication error between MB boards due to defective connection or defective…C2Communication error between MB and ADB boards due to defective connection or…C3Warning code displayed when an error occurs within the appliance allowing…C8Internal communication bus defective due to defective circuit between MB and…Ci4Inductor NTC defective due to NTC not connected or NTC failure.Ci9Inductor incorrectly connected, not connected, defective, or ADB board…E0Input relay defective due to defective MB.E1Incorrect voltage measurement due to defective MB.E10Incorrect NTC temperature of the inductor due to crosswise NTC connections or…E11Inductor relay error due to defective ADB.E12Error code related to adaptation board (ADB) operation and capacitor damages…E13Error in the pan detection system due to defective ADB.E14Software security error (not relevant cause).E15Flash data is not valid; appears when flashing process was interrupted or not…E16Error code listed in table of contents for FSI hob.E2Mains voltage synchronisation error due to defective MB.E3Software security error (not relevant cause).E4ASIC communication error due to defective MB.E5Error code related to adaptation board (ADB) operation; improved behavior…E6Error caused by a damaged main board (MB).E7NTC resistance error of the heat sink in the MB due to defective MB.E8Incorrect current measurement due to defective MB.E9NTC resistance error of the ambient temperature due to defective MB or ADB.W0Input voltage is above 280V due to mains voltage too high or connection/wiring…W1Input voltage is below 160V due to mains voltage too low or connection/wiring…W2Overheating of the inductor due to incorrect installation or overheating…W3Overheating of the induction electronics (MB or ADB boards).W4Over temperature in the user interface caused by hot utensil or high heat…W5Input voltage measured on the user interface is over the limit value due to…View all 31 error codes
Service modes (9)
- Demo mode (Showroom mode)Demo mode can be activated only within the first 3 minutes after the hob is connected to the power…
- Diagnostic ProgramAccessed via the service program
- Flashing (Firmware Update)1
- Service ProgramError codes and service programs are described in a separate document available as an electric…
- Standard Settings MenuRequirement
- Technical Service Programme - BoschNormal activation
- Technical Service Programme - Gaggenau/SiemensNormal activation
- Technical Service Programme - NEFFNormal activation
- Technical Service Programme - ThermadorNormal activation
Full entry steps, exit procedures, and test sequences are available in Max.
Related Thermador cooktop models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass