mypros+
Model reference

Thermador PO301

Oven

5 documents32 error codes4 service modes

Available documentation

Service Manual

  • USE AND CARE MANUAL - Built-in Ovens120 pg
    Covers this model
  • SERVICE MANUAL for Thermador Professional Series Built-in Wall Ovens21 pg
    Covers this model
  • ServiceManualThermProBIWO RevA321 pg
    Covers this model
  • SERVICE MANUAL for Thermador Professional Series Built-in Wall Ovens21 pg
    Covers this model

Training

  • Training Program for Professional & Masterpiece Series Ovens69 pg
    Covers this model
MyPros+ Max

Diagnose your Thermador PO301.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (32)

CodeMeaning
E000Control module and user interface are mismatched (wrong module combination).E003User interface electronics exceed 185°F/85°C (electronics too hot).E005Loss of communication between user interface and control module.E009ROM check error in user interface (start-up error).E010Data memory error in user interface.E011Continuous pushing of a single key detected.E012Defective user interface PCB temperature sensor.E014ON/OFF key does not work.E032Continuous pushing of multiple keys detected (10 seconds of multiple keys being…E101Cavity 1 temperature sensor open.E104Cavity 1 temperature sensor shorted.E106Cavity 1 door latch does not lock.E107Cavity 1 door latch does not unlock.E115Cavity 1 temperature in unlocked cavity too high.E116Cavity 1 meat probe error; standard probe module is part of the control module.E118Cavity 1 cooling fan supervision error (cooling fan speed is too low or too…E122Cavity 1 probe sensor temperature too high.E123Cavity 1 probe sensor temperature too low.E124Cavity 1 door switch error (door switch is in undefined state).E126Cavity 1 door latch error (door latch is in an undefined state).E201Cavity 2 temperature sensor open.E204Cavity 2 temperature sensor shorted.E206Cavity 2 door latch does not lock.E207Cavity 2 door latch does not unlock.E215Cavity 2 temperature in unlocked cavity too high.E218Cavity 2 cooling fan supervision error (cooling fan speed is too low or too…E224Cavity 2 door switch error (door switch is in undefined state).E226Cavity 2 door latch error (door latch is in an undefined state).E303Control module electronics exceed 212°F/100°C (electronics too hot).E309ROM check error in control module.
View all 32 error codes

Service modes (4)

  • Demo Mode["The display and lights will work on 120VAC when the black and red wires are tied together."]
  • Service Mode["Set oven mode knob(s) to OFF.","Set upper oven temperature knob to 100°.","Press SELECT, up…
  • Temperature Offset Adjustment (Cavity 1)["Simultaneously press FAST PREHEAT and ▲ for 5 seconds.","Confirm that Upper is correctly…
  • Temperature Offset Adjustment (Cavity 2)["Simultaneously press FAST PREHEAT and ▼ for 5 seconds.","Confirm that Lower is correctly…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass