Model reference
Whirlpool W11040040A
Dryer
1 document18 error codes3 service modes
Available documentation
Service Manual
- ServiceManual W11040040 RevA68 pg
MyPros+ Max
Diagnose your Whirlpool W11040040A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (18)
CodeMeaning
F01Main relay defect on the ACU.F02Corrupted EEPROM on the ACU.F03Humidity (moisture) sensor failure.F04Relay failure (K002 or K003).F06Heat Exchanger (HX) NTC (thermistor) value too high or too low.F07Motor movement defect or broken drum belt.F10MCU communication error (no communication between ACU and MCU).F11MCU motor failure.F12MCU not reset.F14Undervoltage condition detected.F15MCU failure (rectifier diode shorted/open).F18MCU over temperature.F19MCU over voltage.F20Motor over current.F21UI communication error (no communication between ACU and UI).F22ACU communication error (no communication between ACU and UI).F23Compressor defect.F24Fan defect (post condenser fan).Service modes (3)
- Customer-Focused Dryness Level Adjustment["Press POWER.","Press and hold the PROGRAM button as the dryer counts down '3-2-1' before…
- Reset Procedure["Turn on the dryer.","Press and hold POWER until '3-2-1' and then 'rES' appears in the…
- Service Diagnostic Mode / Service Test Cycle["Ensure dryer is in standby mode (plugged in with all indicators off).","Open and close the dryer…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands