Tech Sheet
- Whirlpool Control Panel Service Technical Sheet56 pg
Service Flash
- Steam Dryer Hose Kit6 pg
Tech Tip
- Instruction Sheet2 pg
- Instruction Sheet4 pg
- Instruction Sheet - W10318609- Rev A - Special Handling7 pg
Installation Guide
- Instrucciones de instalacion19 pg
MyPros+ Max
Diagnose your Whirlpool YWED94HEXL2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (19)
CodeMeaning
AFRestricted air flow detected that may affect dryer performance.F1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Stuck button (depressed for over 20 seconds) or UI mismatch; only appears in…F2E2UI cannot read EEPROM software from UI.F2E3Main control EEPROM is not programmed correctly.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; occurs if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 30V) detected at the CCU.F6E1Communication between the CCU and UI has not been detected (UI to CCU…F6E2Communication between the CCU and UI has not been detected (CCU to UI…L2Low L2 voltage (less than 30V) detected at the CCU.PFPower failure occurred while the dryer was running.Service modes (6)
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Fault/Error Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button used to activate…
- Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Service Diagnostic Mode["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands