Model reference
Whirlpool W11382324A
Range
1 document24 error codes7 service modes
Available documentation
Tech Sheet
- Tech Sheet - W1138232448 pg
MyPros+ Max
Diagnose your Whirlpool W11382324A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (24)
CodeMeaning
C-81Induction cooktop over temperature (Type 2 failure).C-82Induction cooktop over temperature (Type 2 failure).C-83Induction cooktop temperature sensor stuck (Type 2 failure).F-12Induction cooktop coil under current (Type 1 failure, affects only one burner).F-21Induction cooktop supply power frequency error (Type 2 failure, affects all…F-25Stuck fan on Induction Power System (IPS)F-36Induction cooktop temperature sensor is not working (Type 1 failure, affects…F-37Induction cooktop temperature sensor is not working (Type 1 failure, affects…F-40Induction Power System (IPS) failure (Type 1 or Type 2 failure).F-42Induction cooktop power supply error (Type 2 failure).F-43Induction cooktop under voltage (Type 2 failure).F-47Power supply from Induction Power Control (IPC) to User Interface is missing…F-56Wrong or invalid configuration (Type 3 failure, disables entire cooktop).F-58Wrong or invalid configuration (Type 2 failure).F-60UI does not work (Type 3 failure, disables entire cooktop).F1E0EEPROM Communication ErrorF2E0Keypad DisconnectedF2E1Stuck KeypadF3E0Main Oven Sensor Open or ShortedF3E2Drawer Sensor Open or ShortedF6E1Over TempF8E0Cooling Fan Speed Too LowF8E2Cooling Fan Speed Too HighF9E0MiswiredService modes (7)
- Auto Test (Automatic Diagnostic Test)Enter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds)
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Fault Code ClearingEnter Diagnostic Mode by pressing CANCEL>CANCEL>START within 5 seconds
- Fault Code Viewing and ClearingEnter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds)
- Temperature CalibrationPress Settings or Options keypad until 'Temp Calib' is displayed
- Temperature Calibration ModePress the Settings or Options keypad until 'Temp Calib' is displayed
- Test Mode (Manual Relay Activation)Enter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds). Press number 3 or 6 keypads until…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass