Model reference
Whirlpool YGY396LXGQ2
Range
1 document12 error codes3 service modes
Available documentation
Tech Sheet
- Whirlpool Range YGY396LXGQ2 Tech Sheet8 pg
MyPros+ Max
Diagnose your Whirlpool YGY396LXGQ2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (12)
CodeMeaning
F1 E0EEPROM communications error.F1 E1EEPROM checksum failure.F1 E2UL A/D error(s).F2 E0Shorted key detected on keypad.F2 E1Keytail unplugged from control board.F3 E0Oven temperature sensor circuit is open.F3 E1Oven temperature sensor is shorted.F3 E2Bake range over temperature condition.F3 E3Clean range over temperature condition.F5 E0Door switch and latch switch do not agree (mismatch).F5 E1Door lock solenoid not operating or latch switch failure.F5 E2Latch during CLEAN errorService modes (3)
- Clear F5 Failure Code from MemoryPress and hold any key for 1 minute
- Last Error Code RecallPress and hold the CANCEL/OFF key for 5 seconds
- Temperature Calibration AdjustmentPress and hold the BAKE pad for 5 seconds. Current offset is shown on the 3-digit display. 'CAL' is…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax