Model reference
Whirlpool YKERS202BSS1
Range
6 documents13 error codes16 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10478478 - Rev A (FR)8 pg
- Tech Sheet - W10478474 - Rev A8 pg
Tech Tip
- Oven Cleaning Quick Reference Guide2 pg
Installation Guide
- Installation Instructions16 pg
- Instruction Sheet2 pg
Quick Reference
- Quick Reference Manual2 pg
MyPros+ Max
Diagnose your Whirlpool YKERS202BSS1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (13)
CodeMeaning
F1-E0EEPROM communication error.F1-E5Sensor out of range.F1-E7PCB thermistor open or shorted.F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Cancel key error.F3-E0Main oven sensor open or shorted.F3-E2Warming drawer sensor open or shorted.F5-E0Door and switch do not agree (Clean mode—on some models).F6-E1Over temperature during cook mode.F6-E2Over temperature during clean mode.F6-E3Over temperature (warming drawer).F9-E0Mis-wired house or range.Service modes (16)
- Auto Test1
- CONTROL RESETEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 6 'CONTROL RESET'.
- Diagnostics Mode (MRC Control)Press CANCEL > CANCEL > START
- DISPLAYEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 5 'DISPLAY'.
- ENG MODEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 2 'ENG MODE'
- ENG MODE (Engineering Mode)From diagnostic mode, scroll to step 2 'ENG MODE'
- FAULTSEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 7 'FAULTS'.
- MRC Control Module Diagnostic ModePress CANCEL > CANCEL > START
- RELAY USAGEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 8 'RELAY USAGE'.
- Temperature Adjustment1
- TEST MODEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 3 'TEST MODE'
- TEST MODE (Relay Control)From diagnostic mode, scroll to step 3 'TEST MODE'
- TEST ON (Relay Checks)Upon entry to Diagnostics Mode (CANCEL > CANCEL > START), 'TEST ON' is displayed
- TEST ON (Relay Control)Enter diagnostic mode (CANCEL>CANCEL>START)
- USAGEEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 1 'USAGE'.
- VERSIONEnter Diagnostics Mode (CANCEL > CANCEL > START), scroll to service mode 4 'VERSION'.
Full entry steps, exit procedures, and test sequences are available in Max.