25 documents96 error codes33 service modes
Available documentation
Service Manual
- Integrated Module (Prior to 2015) Service Manual94 pg
- Technical Service Manual (Including Parts List & Exploded Views) - Induction Cooktop CT15I38 pg
- Service Manual Integrated Module Prior to 20155 pg
- CT Induction Cooktop Service Manual22 pg
- Wolf Original CT15I: Prior to Serial 16000000 — Service Manual21 pg
- Integrated Cooktops Technical Service Manual74 pg
- Electric Cooktops (CTE) Series Technical Service Manual48 pg
- Wolf Service Manual: ICB CT Induction Cooktop — Service Manual39 pg
- Technical Service Manual (Including Parts and Exploded Views) - Integrated Cooktops120 pg
- Wolf CT Induction Enhancements 1: Serials 16000000 to 17599999 — Service Manual41 pg
- Wolf CT Induction Enhancements 2: After Serial 17600000 — Service Manual38 pg
- Service Manual Electric Cooktop (CTE) Series4 pg
- Service Manual CT Induction Cooktop 1 44 pg
- Electric Cooktops Technical Service Manual (Including Parts and Exploded Views)58 pg
- Wolf Service Manual: Integrated Module (Prior to 2015) — Service Manual93 pg
- Technical Service and Parts Manual Electric Cooktop-2 Series62 pg
- Wolf Original: Prior to Serial 17000000 — Service Manual34 pg
- Wolf Original: Prior to Serial 11103817 — Service Manual33 pg
- Wolf CT/G-2: Serials 11103817 to 16999999 — Service Manual33 pg
- Wolf CT/G-3: Serials 11103817 to 16999999 — Service Manual34 pg
Other
- wolf induction cooktop62 pg
Installation Guide
- Wolf Gas Cooktop High Altitude Conversion Package For 8,000 - 11,000 Feet Installation Instructions2 pg
Parts Manual
- Wolf Original: Prior to Serial 11103817 — Parts Manual4 pg
- Wolf CT/G-3: After Serial 17000000 — Parts Manual6 pg
- Wolf CT/G-2: Serials 11103817 to 16999999 — Parts Manual6 pg
MyPros+ Max
Diagnose your Wolf CT36G/S-LP.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (96)
CodeMeaning
1Comm Error2Off Key Error3RTD1 Open Error4RTD1 Short Error5RTD2 Open Error6RTD2 Short Error7Overtemp Error8Communications with the Glass-Touch interface chip have failed9An error was detected with the global off key.E01Power module ambient temperature has reached or exceeded its temperature limit…E02Power module heat sink temperature has reached or exceeded its temperature…E05Power module ambient temperature sensor indicates a disconnected (open) sensor.E06Power module ambient sensor is shorted to heatsink sensor.E07The power module reports an inconsistent model value to the display board.E08Display board is unable to communicate to the keyboard.E09Keyboard internally detects communications errors and reports this back to the…E1Ambient temperature too high; unit enters Lock Mode until ambient temperature…E10Generator 3 communication error; burners associated with generator 3 disabled.E11A/D failure; cooktop enters Lock Mode and displays error code in timer display.E12Universal OFF button failure; watchdog timer not reset on key release within…E13Shorted key failure; watchdog timer not reset on key release, affected burner…E14Keyboard detects internal EEPROM failure and reports to the display board.E15Keyboard internally recalibrates periodically and reports calibration failure…E16Keyboard internally detects CRC communications errors and reports this back to…E17Failure of the Keep Alive capacitor to discharge after a Keep Alive recovery…E18Power board EEPROM CRC failure; EEPROM records individually tested with…E19Read line failure; control enters Lock Mode and displays error until corrected.E2Generator 1 heatsink temperature too high; burners unavailable until heatsink…E20Generator 1 burner (F,FR,FC) sensor shorted; affected burner shuts down when…E21Generator 2 burner (FL) sensor shorted; affected burner shuts down when A/D…View all 96 error codes
E22Generator 1 burner (F,FR,FC) sensor open; affected burner shuts down when A/D…E23Generator 2 burner (FL) sensor open; affected burner shuts down when A/D value…E3Generator 2 heatsink temperature too high; burners unavailable until heatsink…E30Generator 1 burner (F,FR,FC) ON LED failure; affected burner not available.E31Generator 1 burner (R,RR,RC) ON LED failure; affected burner not available.E32Generator 2 burner (RL) ON LED failure; affected burner not available.E33Generator 2 burner (FL) ON LED failure; affected burner not available.E34Generator 3 burner (RR) ON LED failure; affected burner not available.E4Generator 3 heatsink temperature too high; burners unavailable until heatsink…E40Generator 1 burner (R,RR,RC) sensor shorted; affected burner shuts down.E41Generator 2 burner (RL) sensor shorted; affected burner shuts down.E42Generator 3 burner (RR) sensor shorted; affected burner shuts down.E43Generator 1 burner (R,RR,RC) sensor open; affected burner shuts down.E44Generator 2 burner (RL) sensor open; affected burner shuts down.E45Generator 3 burner (RR) sensor open; affected burner shuts down.E5Open ambient thermistor detected (recorded after 5 minutes of consecutive open…E50Generator 1 open heat sink thermistor; affected burner shuts down.E51Generator 2 open heat sink thermistor; affected burner shuts down.E52Generator 3 open heat sink thermistor; affected burner shuts down.E53Generator 1 shorted heat sink thermistor; affected burner shuts down.E54Generator 2 shorted heat sink thermistor; affected burner shuts down.E55Generator 3 shorted heat sink thermistor; affected burner shuts down.E56Power module microcontroller Flash memory CRC failure.E57Display board microcontroller Flash memory CRC failure.E58Power module microcontroller configuration fuse failure.E59Display board microcontroller configuration fuse failure.E6Shorted ambient thermistor; if A/D value exceeds error limit, unit enters Lock…E60Power module internal error (invalid internal state).E63Display board zero-cross signal failure.E64Self test resultE65Self test resultE66Self test resultE67Self test resultE69Power module microcontroller internal RAM/Register error.E7Diode configuration error; cooktop keyboard shows incorrect diode configuration.E70Display board microcontroller internal RAM/Register error.E71Self test resultE72Self test resultE73Self test resultE74Self test resultE75Self test resultE76Self test resultE77Self test resultE78Self test resultE79Self test resultE8Generator 1 communication error; burners associated with generator 1 disabled.E80Self test resultE81Self test resultE82Self test resultE83Self test resultE84Self test resultE9Generator 2 communication error; burners associated with generator 2 disabled.F1Shorted Temperature Sensor on front Cooking Zone.F2Open Temperature Sensor on front Cooking Zone.F3Shorted Temperature Sensor on rear Cooking Zone.F4Open Temperature Sensor on rear Cooking Zone.F5Shorted Temperature Sensor as check on transistors.F6Open Temperature Sensor as check on transistors.F7Temperature of electronics exceeded 158°F (70°C) during operation.F8Temperature Sensors are interchanged during assembly or after a service call.F9Mains voltage Vrms < 180V.FATimeOut communication error.FBCheck sum error.FCBoost LED Error.FDLock LED Error.LoLow liquid/oil level detected or dry start condition; pan and liquid RTD…
Service modes (33)
- Annunciator Setup (User Options)1
- Clear Error Codes - Steamer/Fryer["Press CLEAR touch pad.","Press '-' touch pad of the u-shaped bar LED.","Press and hold '+' touch…
- diagnostic1. Cooktop must be in LOCK mode. 2. Touch and hold the [OFF] keypad for 5 seconds. 3. A beep will…
- Diagnostic Mode1
- Diagnostic Mode - Electric Fryer (IF15)["Ensure cooktop is in Lock Mode.","Press CLEAR touch pad and release.","Within 2 seconds, press…
- Diagnostic Mode - Electric Grill (IG15)["Ensure cooktop is in Lock Mode.","Press and hold the CLEAR touch pad for 5 seconds.","Release…
- Diagnostic Mode - Electric Steamer (IS15)["Ensure cooktop is in Lock Mode.","Press CLEAR touch pad and release.","Within 2 seconds, press…
- diagnostic_mode_1Enter diagnostic mode (LOCK mode + hold OFF Key 5 seconds)
- diagnostic_mode_1_checking_LEDsEnter diagnostic mode (see above)
- diagnostic_mode_15While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 15.
- diagnostic_mode_15_software_versionWhile in diagnostic mode, touch the + keypad on the 1200W control to advance to Mode 15.
- diagnostic_mode_2While in diagnostic mode, touch the OFF/ON or '+' Key on the 1200W control to enter Mode 2.
- diagnostic_mode_2_checking_cooling_fanWhile in diagnostic mode, touch the ON/OFF or + keypad on the 1200W control to enter Mode 2.
- diagnostic_mode_3While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 3.
- diagnostic_mode_3_electronic_hardware_versionWhile in diagnostic mode, touch the + keypad on the 1200W control to advance to Mode 3.
- diagnostic_mode_4While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 4.
- diagnostic_mode_4_ambient_temperature_thermistorWhile in diagnostic mode, touch the + keypad on the 1200W control to advance to Mode 4.
- diagnostic_mode_5While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 5.
- diagnostic_mode_5_heatsink_thermistorWhile in diagnostic mode, touch the + keypad on the 1200W control to advance to Mode 5.
- diagnostic_mode_6While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 6.
- diagnostic_mode_6_lid_switchWhile in diagnostic mode, touch the + keypad on the 1200W control to advance to Mode 6.
- diagnostic_mode_7While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 7.
- diagnostic_mode_7_last_error_codeWhile in diagnostic mode, touch the + keypad on the 1200W control to advance to Mode 7.
- diagnostic_mode_8_through_14_preceding_error_codesWhile in diagnostic mode, touch the + keypad on the 1200W control to advance through Modes 8-14.
- diagnostic_mode_8_to_14While in diagnostic mode, touch the '+' Key on the 1200W control to advance through Modes 8-14.
- Diagnostics Mode["Ensure cooktop is in Lock Mode.","Touch and hold the 'OFF' keypad for 5 seconds.","A beep will…
- Fahrenheit to Celsius Conversion (Steamer/Fryer)["Verify unit is in LOCK mode.","Press CLEAR touch pad once, then immediately press LOW touch pad…
- Fahrenheit to Celsius Display Change - Steamer/Fryer["Verify unit is in LOCK mode.","Press CLEAR touch pad once, then immediately press LOW touch pad…
- lockTouch and hold the [Key] symbol for 3 seconds
- Lock Mode["Touch and hold the 'Key' symbol for 3 seconds.","The unit will beep three times and the light…
- showroom1
- Showroom Mode1
- User Options (Annunciator Volume/Frequency Adjustment)["Cooktop must be in Idle Mode.","Touch and hold 'CLEAR' pad for 3 seconds to activate Volume…