Error code reference
Electrolux Cooktop Error Code E032
Power supply defect, Induction Housing Assembly / Left side cooking zones.
Power supply defect, Induction Housing Assembly / Left side cooking zones.
First step from the service manual
1
Test all cables & connections on Filter Circuit Board.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
MyPros+ Max
Get the full diagnostic procedure for E032.
- ✓Step-by-step tests with expected resistance, voltage, and continuity values
- ✓Wiring diagram references and connector pinouts from the OEM service manual
- ✓Verified part numbers when replacement is required
Get the full procedure→
$29/month · Cancel anytime · Or $9.95 3-day pass
M+
M+ Max·Electrolux Cooktop
E032 on my Electrolux Cooktop
M+
Power supply defect, Induction Housing Assembly
From Service Manual 869454, p.26:
1.Test all cables & connections on Filter Circuit Board.
2.Measure line voltage at the power cord terminal block. Expected: 120 VAC (L1 to neutral) or 208 to 240 VAC between L1 and L2 under load.
3.Inspect the cord strain relief and terminal block screws for signs of arcing or heat discoloration. Loose connections here mimic an intermittent power failure to the control board.
Part 5304502778
Power cord
Related Electrolux cooktop codes
All Electrolux cooktop codes →- 10Center zone control defective or key sensor defective.
- 11Center zone control defective or On/Off key sensor…
- 12Center zone control or On/Off key sensor defective.
- 14RR zone control defective or key sensor defective.
- 15RR zone control defective or On/Off key sensor defective.
- 16RR zone control or On/Off key sensor defective.
- 17RF zone control defective or key sensor defective.
- 18RF zone control defective or On/Off key sensor defective.
View all 134 Electrolux cooktop codes
- 19RF zone control or On/Off key sensor defective.
- 2LF zone control defective or key sensor defective.
- 21Timer or key sensor defective.
- 22Timer or On/Off key sensor defective.
- 23Keep Warm key sensor defective or On/Off key sensor…
- 24Lock key sensor defective or On/Off key sensor defective.
- 25Main POWER On/Off key sensor defective.
- 3LF zone control defective or On/Off key sensor defective.
- 30Improper power supply (high voltage) or jumper connections.
- 31Power level failure.
- 32Low voltage output from 12V supply on filter board.
- 33Improper voltage output from 5V filter board.
- 34Communication failure between filter board and power boards.
- 35Improper power supply (low voltage) or jumper connections.
- 36Communication error between main touch control and filter…
- 39Touch control board software configuration does not match…
- 4LF zone control or On/Off key sensor defective.
- 40Communication failure between main touch control and filter…
- 51Element temperature sensor break (LF).
- 52Element temperature sensor break (LR).
- 53Element temperature sensor break (Center).
- 54Element temperature sensor break (RR).
- 55Element temperature sensor break (RF).
- 6LR zone control defective or key sensor defective.
- 7LR zone control defective or On/Off key sensor defective.
- 8LR zone control or On/Off key sensor defective.
- EGeneral error code displayed on element screens (E) while…
- E00Error code displayed as E on cooking zone displays and 00…
- E011Jammed key detected on the touch panel.
- E014Touch Panel Tail missing.
- E015ESEC self test failure.
- E021LIN (Local Interconnect Network) error, no communications…
- E03Error code displayed as E on cooking zone displays and 03…
- E030AC input voltage too high, Induction Housing Assembly (left…
- E031Internal generator error, sync, Induction Housing Assembly…
- E033Power supply defect, Induction Housing Assembly / Left side…
- E034Internal generator error, communication, Induction Housing…
- E035AC input voltage too low, Induction Housing Assembly (left…
- E036Communication error, Induction Housing Assembly / Left side…
- E037Heat sink temperature sensor break, Induction Housing…
- E039Configuration mismatch between the ESEC-UIB and the…
- E04Error code displayed as E on cooking zone displays and 04…
- E05Error code displayed as E on cooking zone displays and 05…
- E051Inductor temperature sensor break (Left Front).
- E052Inductor temperature sensor break (Left Rear).
- E054Inductor temperature sensor break (Right Rear).
- E055Inductor temperature sensor break (Right Front).
- E06Error code displayed as E on cooking zone displays and 06…
- E061Left Front inductor temperature sensor too hot.
- E062Left Rear inductor temperature sensor too hot.
- E064Right Rear inductor temperature sensor too hot.
- E065Right Front inductor temperature sensor too hot.
- E07Error code displayed as E on cooking zone displays and 07…
- E070AC input voltage too high, Induction Housing Assembly…
- E071Internal generator error, sync, Induction Housing Assembly…
- E072Power supply defect, Induction Housing Assembly / Right…
- E073Power supply defect, Induction Housing Assembly / Right…
- E074Internal generator error, communication, Induction Housing…
- E075AC input voltage too low, Induction Housing Assembly (right…
- E076Communication error, Induction Housing Assembly / Right…
- E077Heat sink temperature sensor break, Induction Housing…
- E10Center zone control defective key sensor.
- E11Center zone control defective key sensor.
- E12Center zone control key sensor defective.
- E14Right Rear zone control defective key sensor.
- E15Right Rear zone control defective key sensor.
- E16Right Rear zone control key sensor defective.
- E17Right Front zone control key sensor defective.
- E18Right Front zone control key sensor defective.
- E19Right Front zone control key sensor defective.
- E2Left Front zone control defective key sensor.
- E21Timer key sensor defective.
- E22Timer key sensor defective.
- E23Keep warm key sensor defective.
- E24Lock key sensor defective.
- E25Main power key sensor defective.
- E3Left Front zone control defective key sensor.
- E30AC input voltage too high at the 3 cook zones induction…
- E31Internal generator error, sync in the 3 cook zones…
- E32Low voltage output from 12V supply on filter board in the 3…
- E33Improper voltage output from filter board in the 3 cook…
- E34Communication failure between filter board and power boards…
- E35AC input voltage too low in the 3 cook zones induction…
- E36Communication error between main touch control and filter…
- E37Heat sink temperature sensor break (3 zones induction…
- E39Configuration mismatch between the User Interface and the…
- E4Left Front zone control key sensor defective.
- E40Communication failure between main touch control and filter…
- E45Incoming power supply low voltage.
- E51Left Front element temperature sensor break.
- E52Left Rear element temperature sensor break.
- E53Center element temperature sensor break.
- E54Right Rear element temperature sensor break.
- E55Right Front element temperature sensor break.
- E6Left Rear zone control defective key sensor.
- E60Touch control general hardware error, keys.
- E61Left Front element temperature sensor too hot.
- E62Left Rear element temperature sensor too hot.
- E63Center element temperature sensor too hot.
- E64Right Rear element temperature sensor too hot.
- E65Right Front element temperature sensor too hot.
- E7Left Rear zone control defective key sensor.
- E70AC input voltage too high at the 3 cook zones induction…
- E71Internal generator error, sync (center cooking zone).
- E72Low voltage output from 12V supply on filter board in the 3…
- E73Improper voltage output from filter board in the 3 cook…
- E74Internal generator error, communication (3 zones induction…
- E75AC input voltage too low in the 3 cook zones induction…
- E76Communication error in the 3 cook zones induction module…
- E77Heat sink temperature sensor break in the 3 cook zones…
- E8Left Rear zone control key sensor defective.
- E80Flash/ROM check fail (EEPROM data).
- E90AC input voltage too high in the 2 cook zones induction…
- E91Internal generator error, sync in the 2 cook zones…
- E9212V on the service section too low in the 2 cook zones…
- E935V overcurrent on the switched 5V on the service section (2…
- E94Internal generator error, communication in the 2 cook zones…
- E95AC input voltage too low in the 2 cook zones induction…
- E96Communication error in the 2 cook zones induction module.
- E97Heat sink temperature sensor break in the 2 cook zones…
- FInduction element utensil detection error
- FXXGeneral error code indicated when element displays show 'F'…
- HResidual heat indicator displayed on cooking zone screen…
- HEHot Element indicator displayed and flashing on ESEC screen…
- PFPower Failure indicator displayed on ESEC screen when the…
- SFSabbath mode power failure recovery indicator
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started →$29/month · Cancel anytime · Or $9.95 3-day pass