mypros+
Error code reference

Frigidaire Cooktop Error Code E95

AC input voltage too low in the 2 cook zones induction module.

AC input voltage too low in the 2 cook zones induction module.

First step from the service manual

Verify AC input voltage at the cooktop input.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for E95.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What E95 means on a Frigidaire cooktop

The E95 error code on a Frigidaire induction cooktop indicates that the AC input voltage detected by the 2 cook zones induction module has dropped below the acceptable operating threshold. Induction cooktops require stable AC line voltage to power the inverter circuits that generate the high-frequency electromagnetic fields used for cooking. When the module detects that the incoming voltage is insufficient, it triggers E95 and disables operation to protect the inverter components from running in an undervoltage condition, which can cause excessive current draw and component damage.

The 2 cook zones induction module is a dedicated power electronics assembly responsible for driving the induction coils in two of the cooktop's burner zones. This module continuously monitors AC input voltage as part of its self-protection logic. If supply voltage falls outside the required operating range, the module reports E95 rather than attempting to operate under degraded conditions. The first diagnostic step is to measure the actual AC input voltage at the cooktop's supply terminals to confirm whether the issue originates upstream in the electrical supply or within the cooktop itself.

Common causes include low household supply voltage from the utility, a weak or failing circuit breaker, loose or corroded wiring connections at the terminal block, or a shared circuit that is overloaded. In some cases, the induction module itself may have a faulty voltage sensing circuit that reports low voltage even when line voltage is within spec, pointing to a module replacement rather than an electrical supply correction.

Source: manufacturer service documentation.

Common causes of E95

  1. 01

    Low household supply voltage

    Wiring / connection

    The utility supply voltage at the home may be sagging below the required level, especially during peak demand periods. Use a multimeter to measure voltage at the cooktop's supply terminals and compare to the rated input requirement.

  2. 02

    Weak or failing circuit breaker

    Part replacement

    A breaker that is beginning to fail can cause a voltage drop on the circuit it controls without fully tripping. If voltage at the panel is normal but voltage at the cooktop terminals is low, the breaker is a likely culprit.

  3. 03

    Loose or corroded wiring connections

    Wiring / connection

    Loose connections at the cooktop's terminal block or in the junction box can create resistance that causes a voltage drop under load. Inspect all supply wire terminations for tightness and signs of heat discoloration or corrosion.

  4. 04

    Overloaded shared circuit

    Wiring / connection

    If the cooktop shares a circuit with other high-draw appliances, the combined load can pull voltage below the module's acceptable threshold. The cooktop should be on a dedicated circuit sized to its rated amperage.

  5. 05

    Faulty induction module voltage sensing

    Part replacement

    If the AC input voltage measures correctly at the supply terminals but E95 persists, the voltage sensing circuit within the 2 cook zones induction module itself may have failed. This condition requires replacement of the induction module.

See the test procedure for each cause

Frequently asked questions about E95

What does E95 mean on a Frigidaire cooktop?
E95 means the 2 cook zones induction module has detected that the AC input voltage is too low to operate safely. The cooktop disables itself to protect the inverter and power electronics from damage caused by undervoltage conditions. The first diagnostic step is to measure the actual supply voltage at the cooktop's input terminals using a multimeter.
Can I fix E95 myself, or do I need a technician?
Some causes of E95, such as an overloaded circuit or a shared circuit issue, can be addressed without a technician. However, measuring voltage at the terminal block, inspecting wiring connections, or replacing a circuit breaker involves working with high-voltage wiring and should only be done by someone comfortable with electrical safety procedures. If the induction module itself has failed, a qualified technician should handle the replacement.
Is it safe to keep using the cooktop when E95 is displayed?
No. The cooktop disables cooking operation when E95 is active precisely because running the induction module under low voltage can cause overheating and component damage. Do not attempt to bypass or ignore the error. Resolve the underlying voltage issue before resuming use.
Will resetting the cooktop clear the E95 error?
A reset may temporarily clear the displayed error, but if the underlying voltage problem has not been corrected, E95 will return as soon as the module attempts to operate again. Clearing the code without addressing the root cause does not protect the appliance and is not a permanent solution.
How much does it cost to repair an E95 error on a Frigidaire induction cooktop?
Repair costs vary depending on the cause. If the issue is a loose connection or a circuit correction with no parts needed, costs may be limited to a service call fee, typically in the range of $75 to $150. If the circuit breaker needs replacement, parts and labor could range from $150 to $300. If the 2 cook zones induction module itself requires replacement, total repair costs including parts and labor can range from $250 to $500 or more depending on the specific model and part availability.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass