Frigidaire Dryer Error Code E74

Inlet Control Thermistor short circuit

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E74 error code actually means

Your Frigidaire dryer has detected a problem with the temperature sensor near the air inlet, specifically that its electrical circuit is showing a short. This means the sensor or its wiring may be damaged, which could cause the dryer to misread temperatures. The dryer has stopped normal operation to protect itself from potential overheating.

Diagnostic procedure

The full E74 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check resistance of Inlet Control Thermistor, and check wiring for short circuit across Thermistor connections. Resistance should be between 47K Ohm and 66K Ohm at room temperature (68-77°F or 20-25°C). Replace Inlet Control Thermistor and/or wiring and retest.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E74 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E74

Ranked by how often they cause this code
  1. 1Failed Inlet Control Thermistor
  2. 2Pinched or damaged wiring harness
  3. 3Corroded or shorted connector pins
  4. 4Heat-damaged wiring near the inlet

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E74

What does E74 mean on a Frigidaire dryer?
E74 indicates that the control board has detected a short circuit in the Inlet Control Thermistor circuit. The thermistor is a temperature sensor that monitors incoming air, and its resistance should measure between 47K and 66K ohms at room temperature. When the board reads resistance far below that range due to a short, it triggers E74 to prevent unsafe operation. The fault points to either the thermistor itself or the wiring connected to it.
Is it safe to run my Frigidaire dryer with an E74 error?
Running the dryer while E74 is active is not recommended. A shorted thermistor means the control board cannot accurately read inlet air temperature, which could lead to improper heating behavior. Continuing to operate the dryer in this state risks inadequate drying performance or, in a worst case, overheating. Address the fault before resuming normal use.
How much does it cost to repair an E74 error on a Frigidaire dryer?
Repair costs depend on whether the fault is in the thermistor or the wiring. A replacement Inlet Control Thermistor typically costs in the range of 15 to 40 dollars for the part alone. If professional labor is involved, total repair costs including diagnosis and installation generally fall in the range of 100 to 200 dollars. Wiring repairs may vary depending on the extent of the damage found.
Can I fix the E74 error myself?
A knowledgeable DIYer can diagnose and often resolve E74 with a multimeter and basic hand tools. The first step is to check the resistance of the Inlet Control Thermistor at room temperature and compare it to the 47K to 66K ohm specification. If the thermistor is out of range, replacing it is a straightforward repair. If the thermistor reads correctly, tracing and repairing the wiring harness requires more careful inspection and may be better handled by a technician.
Will resetting the dryer clear the E74 code?
A reset may temporarily clear the error display, but E74 will return if the underlying short circuit in the thermistor circuit has not been repaired. The control board detects the fault condition each time it monitors the thermistor circuit, so the code will reappear during the next cycle. A permanent fix requires replacing the defective thermistor or repairing the shorted wiring.