E000Wrong module-received data does not correspond with stored defaults.E003Display electronics module too warm-temperature sensor on display electronics module is…E005Communication fault display electronics module-no bus connection between 2 modules or…E009ROM fault display electronics module-following a reset the ROM is checked; if there is a…E010Data fault display electronics module.E012Defective temperature sensor on the control-fault indicated only in Service programme…E035Rotary switch fault-communication between UI and selector switches via serial protocol is…E036Timer signal of 1Hz deviates.E101Sensor break PT1000 cooking compartment sensor 1-all heaters switched off, cooling fan…E104Sensor short-circuit PT1000 cooking compartment sensor 1-all heaters switched off…E116Connection to core temperature sensor interrupted (up to software 1.20 not displayed).E122Core temperature sensor too high (>99°C / 212°F, resistance <1 kohm)-sensor short-circuit…E123Core temperature sensor too low (<-10°C / 50°F, resistance ≈ 200 kohm)-sensor break…E124Door switch fault cooking compartment 1-available query signals do not fulfil criteria.E128Water sensor break-water sensor is not attached; valves are switched off via the float…E129Water sensor short-circuit-water sensor is not attached; valves are switched off via the…E303Power electronics module too warm-temperature sensor on power electronics module is over…E305Communication fault power electronics module-no bus connection between 2 modules or…E309ROM fault power electronics module-following a reset the ROM is checked; if there is a…E310Data failure power electronics-data content loop test or write error.E312Defective temperature sensor on power electronics module.E313Power too high-by means of actuated relays the power electronics module detects whether…E333Waste water tank does not become empty-float switches did not respond within defined time…E334Water in the bottom tray (only BS27x/BS28x fixed water appliances)-sensor not connected…F 71Waste-water tank is not emptied within 1 min; float switch is sticking / drainage pump…F01Temperature sensor interruption (open circuit).F02Temperature sensor reading too high.F03Temperature sensor short-circuit.F04Temperature sensor reading too low.F1Factory or universal comparison necessaryF10Inner oven sensor PT1000 open circuit (EB 270/271, EB 290/291)F11Inner oven sensor PT1000 short circuit (EB 270/271, EB 290/291)F12Food temperature sensor NT50 open circuit; parallel resistance of electronics open (EB…F13Food temperature sensor NT50 short circuit at parallel resistance of electronics or food…F14NTC sensor / electronics open circuit (EB 270/271, EB 290/291)F15NTC sensor / electronics short circuit (EB 270/271, EB 290/291)F16Catalyst sensor PT500 open circuit (EB 270/271, EB 290/291)F17Catalyst sensor PT500 short circuit (EB 270/271, EB 290/291)F18Oven sensor PT 1000 lower oven short circuit of the sensor.F2Fault at the bucket probe / PT500 (VF 230 deep fryer) or fault at the water sensor (VK…F20Operating knob 'operating mode' not chooseableF21Operating knob 'temperature' not chooseableF22CK-control not chooseableF23Relais control not chooseableF3Fault at the limiter / KTY sensor (VF 230 deep fryer) or fault at the steam sensor (VK…F30EEPROM not chooseable or programmableF4Fault at Triac or heating element, or water temperature has not increased by min 5K/41F…F40Information of locking mechanism not available (upper baking oven)F41Programme/temperature switch, door contact switch, locking mechanismF42Door contact switch open circuit although door is locked during pyrolysis (EB 270/271, EB…F43Information locking mechanism not available (lower baking oven)F5Water sensor faulty installedF6Steam sensor faulty installedF61Heating power too low or too much water in inner ovenF62Heating power too high or too little water in inner ovenF63Too little water in inner oven / appliance does not cool downF70Water in the bottom container / sewage container is not pumped outF72Pressure switch defective or main valve does not closeF73Pressure switch permanently indicates pressure when hoses are unpressurized (ED 220/221…F744 dashes in display
Get the full diagnostic procedure for any code
Step-by-step tests, expected values, wiring diagram references, and verified part numbers.
Get Started $9.95 3-day pass$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.