What the F3E5 error code actually means

Your Maytag washer is showing F3E5 because it cannot read the temperature sensors that monitor water inlet and exhaust conditions. Both sensors appear to be disconnected or not working, which causes the machine to stop as a safety precaution. This is often caused by a loose wire connection inside the machine rather than two broken parts.

Diagnostic procedure

The full F3E5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check P14 connector on CCU.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F3E5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of F3E5

Ranked by how often they cause this code
  1. 1Disconnected P14 connector on the CCU
  2. 2Damaged or broken wiring harness
  3. 3Failed inlet thermistor
  4. 4Failed exhaust thermistor
  5. 5Faulty Central Control Unit (CCU)

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about F3E5

What does F3E5 mean on a Maytag washer?
F3E5 means the washer's Central Control Unit is detecting open circuits on both the inlet and exhaust thermistors at the same time. Because both sensors report the same fault simultaneously, a disconnected or faulty P14 connector on the CCU is the most common cause. The machine stops operation when this code appears to prevent running without reliable temperature monitoring.
Is it safe to continue using my washer when the F3E5 code is showing?
You should not continue running the washer while F3E5 is active. The thermistors are responsible for monitoring temperatures during the cycle, and operating without reliable temperature data could allow overheating or improper cycle conditions. Resolve the fault before resuming normal use.
How much does it cost to repair a Maytag washer with an F3E5 error?
Repair costs vary depending on the cause. If only the P14 connector needs to be reseated, there may be no parts cost, and a service call fee could range from around $75 to $150. Replacing a thermistor is generally a lower-cost repair, with parts typically in the $20 to $60 range plus labor. If the CCU itself has failed, parts and labor combined can range from $200 to $400 or more depending on the model and service provider.
Can I fix the F3E5 error code myself?
In many cases, yes. The first step is to check the P14 connector on the CCU to make sure it is fully seated and that the pins are not corroded or damaged. If reconnecting or reseating the connector resolves the issue, no parts are needed. If the wiring harness or a thermistor has failed, those repairs require basic electrical testing with a multimeter and may involve replacing a component.
Will resetting the washer clear the F3E5 error code?
A reset may temporarily clear the code, but it will return if the underlying cause is not corrected. If the P14 connector is loose or a thermistor has failed, the fault condition still exists and the code will reappear once the machine attempts to run. Address the root cause before relying on a reset to restore normal operation.