Samsung Air Conditioner Error Code 18

BLDC compressor starting/rotation error.

BLDC compressor starting/rotation error.

First step from the service manual

Check compressor wire and TAB terminal connections; check service valve open; check EEV motor attachment and connector; replace compressor if locked.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 18.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 18 means on a Samsung air conditioner

Samsung error code 18 on a BLDC (brushless DC) compressor system indicates a starting or rotation failure. BLDC compressors rely on precise electronic commutation signals from the inverter control board to initiate and maintain rotation. When the control board attempts to start the compressor and does not detect the expected rotor feedback confirming successful rotation, it triggers error code 18 and halts operation to prevent damage to the compressor windings or inverter components.

The most common entry points for this fault are wiring and connection issues between the inverter board and the compressor terminals. A loose or corroded TAB terminal connection can disrupt the voltage signals required to drive the compressor's motor phases. Similarly, a closed or partially closed service valve will prevent refrigerant flow, causing the compressor to load up against high head pressure and fail to rotate. An improperly seated EEV (electronic expansion valve) motor or a disconnected EEV connector can also cause refrigerant distribution problems that load the compressor at startup.

If all wiring, connections, service valves, and the EEV are confirmed to be in good condition and properly connected, the fault likely points to a mechanically or electrically locked compressor. A locked compressor may have seized internal components or shorted motor windings, and in that case the compressor must be replaced. Resistance testing across the compressor terminals can help confirm winding integrity before condemning the unit.

Source: manufacturer service documentation.

Common causes of 18

  1. 01

    Loose or corroded compressor wiring or TAB terminal connections

    Wiring / connection

    Poor electrical contact at the compressor terminals or TAB connectors can interrupt the phase signals the inverter sends to start and run the BLDC motor. Inspect all wiring harness connectors and terminal contacts for looseness, corrosion, or heat damage.

  2. 02

    Closed service valve

    Wiring / connection

    If a service valve on the refrigerant circuit is fully or partially closed, the compressor starts against abnormal pressure and cannot build rotation. Verify both the liquid and suction service valves are fully open.

  3. 03

    EEV motor detachment or disconnected EEV connector

    Wiring / connection

    The electronic expansion valve controls refrigerant flow into the indoor coil, and if its motor is not properly attached or its connector is loose, refrigerant distribution is disrupted and the compressor can fail to start under the resulting load. Check that the EEV motor is firmly seated and its connector is fully engaged.

  4. 04

    Mechanically locked compressor

    Part replacement

    Internal seizure of the compressor's scroll or piston components will prevent rotation entirely. If all external checks pass, test compressor winding resistance across terminals and compare values. Unbalanced or shorted windings confirm a locked or failed compressor requiring replacement.

  5. 05

    Failed inverter control board

    Part replacement

    The inverter board generates the commutation signals required to drive the BLDC compressor. If the board has a damaged output stage, it may be unable to produce adequate drive voltage even when the compressor and wiring are intact.

See the test procedure for each cause

Frequently asked questions about 18

What does 18 mean on a Samsung air_conditioner?
Error code 18 on a Samsung air conditioner indicates a BLDC compressor starting or rotation error. This means the system's inverter control board attempted to start the compressor but did not receive confirmation that the compressor rotor was spinning correctly. The cause can range from a loose wiring connection or closed service valve to a failed compressor that must be replaced.
Can I fix error code 18 on my Samsung air conditioner myself?
Some causes of error code 18 can be addressed without specialized tools, such as verifying that service valves are fully open or reseating a disconnected EEV connector. However, testing compressor winding resistance, diagnosing inverter board output, and replacing a locked compressor all require electrical knowledge and proper equipment. Refrigerant-related work also requires EPA certification in the United States, so a licensed HVAC technician should handle the repair if the issue goes beyond basic connection checks.
Is it safe to keep running my air conditioner when error code 18 appears?
No. When error code 18 is active, the system shuts down operation to protect the compressor and inverter board from damage caused by repeated failed start attempts. Attempting to bypass or ignore the fault and force the unit to run could cause additional damage to the inverter components or burn out the compressor windings entirely. Leave the unit off until the fault has been diagnosed and resolved.
Will resetting my Samsung air conditioner clear error code 18?
A power reset may temporarily clear the displayed error and allow the unit to attempt a restart, but if the underlying cause such as a locked compressor, closed valve, or wiring fault has not been corrected, the error will return as soon as the system tries to start again. Repeated failed start attempts can worsen damage to the compressor or inverter board, so resetting without diagnosing the root cause is not recommended.
How much does it cost to repair a Samsung air conditioner with error code 18?
Repair costs vary widely depending on the cause. If the fix is a reconnected wire or opened service valve, the cost is primarily the technician's diagnostic labor, typically in the range of $75 to $150. If the EEV needs replacement, parts and labor can range from $150 to $400. A compressor replacement is the most expensive outcome, often ranging from $600 to $1,500 or more depending on the model and whether refrigerant recovery and recharge are required.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass