mypros+
Error code reference

Samsung Air Conditioner Error Code 320

OLP sensor error (Open/Short).

OLP sensor error (Open/Short).

First step from the service manual

Check for OLP sensor wire cut off.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 320.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 320 means on a Samsung air conditioner

Error code 320 on a Samsung air conditioner indicates an OLP (Over Load Protector) sensor fault, specifically an open circuit or short circuit condition in the sensor or its wiring. The OLP sensor monitors the compressor for excessive current draw or overheating conditions, acting as a safety device to prevent compressor damage. When the control board detects that the signal from the OLP sensor is outside the expected range, either reading as a completely broken circuit (open) or a dead short, it triggers error code 320 and shuts down operation to protect the system.

The most immediate diagnostic step is to inspect the OLP sensor wiring harness for any visible damage, cuts, pinching, or disconnected connectors. A wire cut or broken connector will cause an open circuit reading at the control board. A short circuit can occur when two conductors in the harness make unintended contact, or when moisture or physical damage compromises the sensor itself.

If the wiring appears intact, the OLP sensor component itself may have failed internally, presenting either an open or shorted resistance value outside the acceptable range for the control board. The sensor is typically located on or near the compressor. Testing with a multimeter can confirm whether the sensor resistance is within spec or has failed open or shorted. Replacement of the sensor or wiring harness is generally required if either tests outside acceptable parameters.

Source: manufacturer service documentation.

Common causes of 320

  1. 01

    Cut or broken OLP sensor wire

    Part replacement

    Physical damage to the OLP sensor wiring harness is the first thing to check. A cut, pinched, or severed wire creates an open circuit that the control board reads as a sensor fault.

  2. 02

    Disconnected wiring connector

    Wiring / connection

    The connector joining the OLP sensor wire to the main harness or control board may have come loose due to vibration or improper servicing. Inspect all connectors in the OLP sensor circuit for secure seating.

  3. 03

    Failed OLP sensor

    Part replacement

    The OLP sensor itself can fail internally, presenting an open or shorted resistance to the control board. If wiring checks out, test the sensor directly with a multimeter to confirm it has failed.

  4. 04

    Short circuit in the sensor wiring

    Part replacement

    Moisture ingress, chafing against sharp metal edges, or rodent damage can cause two conductors in the sensor harness to contact each other, creating a short. Look for burnt insulation or wet areas near the wiring.

  5. 05

    Corrosion at sensor terminals

    Wiring / connection

    Corrosion on the OLP sensor connector pins or terminals can increase resistance to the point where the control board interprets the signal as an open or short fault. Clean corroded contacts and retest before replacing parts.

See the test procedure for each cause

Frequently asked questions about 320

What does 320 mean on a Samsung air conditioner?
Error code 320 on a Samsung air conditioner indicates an OLP (Over Load Protector) sensor error, specifically an open circuit or short circuit condition. The OLP sensor is a safety component associated with the compressor, and when its signal falls outside the expected range, the unit shuts down and displays this code. The fault can be in the sensor wiring, the connector, or the sensor itself.
Can I fix error code 320 myself, or do I need a technician?
A knowledgeable DIYer can start by visually inspecting the OLP sensor wiring for obvious cuts, disconnections, or corrosion, and reseating any loose connectors. However, testing the sensor with a multimeter and accessing the compressor area requires comfort with electrical components and disassembly of the unit. If you are not experienced with HVAC electrical diagnostics, a qualified technician is the safer choice.
Is it safe to keep using my air conditioner when error code 320 is showing?
No, you should not continue operating the unit while error code 320 is active. The OLP sensor is a compressor protection device, and bypassing or ignoring this fault could result in compressor overload or damage. The system will typically prevent operation until the fault is resolved, which is an intentional safety feature.
Will resetting my Samsung air conditioner clear error code 320?
A power reset may temporarily clear the code and allow the unit to attempt a restart, but the error will return if the underlying wiring or sensor fault has not been repaired. Resetting without fixing the root cause does not resolve the problem and may delay necessary repairs. The OLP circuit must be inspected and the faulty component corrected for the code to stay cleared.
How much does it cost to repair error code 320 on a Samsung air conditioner?
Repair costs vary depending on what needs to be replaced. If only a wiring repair or connector replacement is needed, costs tend to be lower, typically in the range of $75 to $150 for labor. Replacing the OLP sensor itself adds parts cost, generally putting the total repair in the $100 to $300 range depending on the model and local labor rates. If the compressor itself has been damaged due to a prolonged fault, costs can be significantly higher.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass