What E318 means on a Samsung air conditioner

Error code E318 on a Samsung air conditioner indicates a low pressure sensor breakaway fault. This means the system has detected that the low-side pressure sensor has become disconnected, lost signal continuity, or is otherwise reading outside its expected range. The low pressure sensor monitors refrigerant pressure on the suction side of the refrigerant circuit, and its data is critical for the control board to manage compressor operation, refrigerant flow, and system protection. When the sensor signal breaks away from its expected parameters, the unit interprets this as a fault condition and halts normal operation to prevent compressor damage.

A breakaway condition can result from a physical disconnection of the sensor's wiring harness, a short or open circuit in the sensor signal wire, corrosion at the connector terminals, or outright sensor failure. In some cases, vibration over time can cause the connector to work loose from the sensor body or from the control board. The sensor itself is a pressure transducer that converts refrigerant pressure into a voltage or resistance signal, so any interruption in that signal path will trigger this code.

Diagnosing E318 requires checking the wiring harness between the low pressure sensor and the main control board for continuity, inspecting connectors for corrosion or looseness, and testing the sensor output signal. If the wiring checks out, the sensor itself may need to be replaced. In rare cases, the control board input circuit for the sensor signal can fail, requiring board-level diagnosis.

Source: manufacturer service documentation.

Common causes of E318

  1. 01

    Disconnected sensor wiring harness

    Wiring / connection

    Vibration or accidental contact can cause the low pressure sensor connector to pull free from the sensor body or the control board. Inspect all connectors along the sensor wiring path for secure seating.

  2. 02

    Failed low pressure sensor

    Part replacement

    The pressure transducer itself can fail internally, producing no signal or an out-of-range signal. Testing the sensor output voltage or resistance against specified values will confirm this failure.

  3. 03

    Corroded or damaged connector terminals

    Wiring / connection

    Moisture ingress at the sensor connector can cause corrosion on the pins, creating high resistance or an open circuit in the signal path. Visually inspect terminals for green or white oxidation and clean or replace as needed.

  4. 04

    Open or shorted sensor signal wire

    Wiring / connection

    Physical damage to the wire running between the low pressure sensor and the control board can break the signal circuit. Perform a continuity check along the entire wire length to locate any break or short to ground.

  5. 05

    Faulty main control board

    Part replacement

    If the sensor, wiring, and connectors all test correctly, the input circuit on the main control board that reads the sensor signal may have failed. This is the least common cause and is diagnosed by process of elimination.

See the test procedure for each cause

Frequently asked questions about E318

What does E318 mean on a Samsung air conditioner?
E318 indicates a low pressure sensor breakaway fault, meaning the control board has lost the signal from the low-side refrigerant pressure sensor. The unit stops normal operation to protect the compressor from running under unknown pressure conditions. The cause is typically a disconnected connector, a damaged wire, or a failed sensor.
Can I fix E318 myself or do I need a technician?
Some causes of E318, such as a loose wiring connector, can be addressed by a knowledgeable homeowner after safely powering down the unit. However, if the fault involves refrigerant handling, sensor replacement inside sealed components, or control board diagnosis, a certified HVAC technician should perform the work. Working inside air conditioning equipment carries electrical and refrigerant safety risks.
Is it safe to run my air conditioner with an E318 error?
No, you should not attempt to run the unit while E318 is active. The low pressure sensor provides critical data that protects the compressor from operating under conditions that could cause serious damage. Continued operation without a functioning pressure sensor risks compressor failure, which is a costly repair.
Will resetting the unit clear the E318 error?
A power reset may temporarily clear the error code, but if the underlying fault with the low pressure sensor or its wiring is still present, the code will return once the system attempts to restart. A reset is useful for confirming whether the fault is intermittent, but it is not a substitute for diagnosing and repairing the root cause.
How much does it cost to repair an E318 error on a Samsung air conditioner?
Repair costs depend on the root cause. If only a connector needs reseating or cleaning, the cost may be limited to a service call fee, typically in the range of $75 to $150. Replacing the low pressure sensor itself generally adds $50 to $200 in parts. If the main control board is at fault, total repair costs can range from $300 to $600 or more depending on the unit model and labor rates in your area.