Samsung Air Conditioner Error Code U200

Communication error between outdoor unit main and sub MICOM or between outdoor units.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the U200 error code actually means

Your Samsung air conditioner has detected that two of its internal computer controllers are not communicating with each other properly. This is an internal electronic issue, not something caused by normal use, and the system has shut down to protect itself. A technician will need to check the power supply and wiring inside the outdoor unit to find the root cause.

Diagnostic procedure

The full U200 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Perform error reset (K3), check 12V and 5V power supply to the affected outdoor unit.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock U200 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of U200

Ranked by how often they cause this code
  1. 1Low or missing 12V or 5V power supply
  2. 2Damaged or disconnected communication harness
  3. 3Faulty sub MICOM or main MICOM control board
  4. 4Inter-unit communication wiring fault in multi-unit systems
  5. 5Transient electrical disturbance

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about U200

What does U200 mean on a Samsung air conditioner?
U200 indicates a communication error between the outdoor unit's main MICOM and sub MICOM controllers, or between multiple linked outdoor units. The two internal computers that coordinate outdoor unit operation have lost contact with each other. The system shuts down to prevent unsafe operation until the communication link is restored. A technician should check the 12V and 5V power supply to the outdoor control board as the first diagnostic step.
Is it safe to keep running the air conditioner with a U200 error?
The system will typically shut down automatically when U200 is active, which is a protective response. Attempting to force the unit to operate while the MICOM communication link is broken could result in uncoordinated compressor and fan behavior. The unit should remain off until a technician has diagnosed and resolved the fault.
How much does it cost to repair a Samsung air conditioner U200 error?
Repair cost depends on the root cause. If the fault is a loose connector or corroded wiring, labor charges for diagnosis and repair might range from $75 to $200. If a control board replacement is needed, parts alone can range from $150 to $500 or more depending on the specific outdoor unit model, with additional labor on top. Getting a diagnostic visit from a certified technician is the best way to get an accurate estimate for your specific situation.
Will resetting the unit clear the U200 error?
A reset using the K3 error reset procedure can clear U200 if it was caused by a temporary power fluctuation or communication glitch. If the underlying cause is a hardware fault such as a failed power supply, damaged wiring, or a defective control board, the error will return shortly after the reset. Always check the 12V and 5V supply voltages after performing the reset to determine whether a hardware problem exists.
How do I fix a U200 error on my Samsung air conditioner?
Start by performing the K3 error reset and observing whether the code returns. If it does, a qualified technician should measure the 12V and 5V DC power supply outputs at the outdoor unit control board. If those voltages are correct, the communication wiring harness between the main and sub MICOM boards should be inspected for damage or loose connectors. In multi-unit systems, the inter-unit communication wiring terminals should also be verified.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass