Samsung Air Conditioner Error Code YEL_FLICKER_GRN_FLICKER

Compressor starting error

Compressor starting error

First step from the service manual

Check compressor TAB terminal connections, service valve, EEV motor

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for YEL_FLICKER_GRN_FLICKER.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What YEL_FLICKER_GRN_FLICKER means on a Samsung air conditioner

The YEL_FLICKER_GRN_FLICKER error code on a Samsung air conditioner indicates a compressor starting error, meaning the system attempted to start the compressor but failed to detect successful startup. This error is signaled by alternating yellow and green LED flickers on the indoor or outdoor unit's diagnostic display. The compressor is the core refrigerant compression component in the refrigeration circuit, and a failure to start it properly prevents the entire cooling or heating cycle from initiating. The control board monitors feedback signals from the compressor circuit to confirm startup, and when that confirmation is absent or out of specification, this code is triggered.

Three primary areas are implicated in this fault: the compressor TAB terminal connections, the service valve position, and the Electronic Expansion Valve (EEV) motor. Loose, corroded, or improperly seated TAB terminal connections at the compressor can prevent adequate electrical contact, resulting in insufficient current delivery to start the compressor motor windings. A closed or partially closed service valve restricts refrigerant flow, which can cause abnormal suction or discharge pressure conditions that prevent the compressor from starting under the resulting load. The EEV motor controls refrigerant flow into the evaporator, and a failed or stalled EEV motor can create pressure imbalances that similarly prevent compressor startup.

Diagnosis should begin at the compressor TAB terminals to verify secure, corrosion-free connections, followed by confirming both service valves are fully open. The EEV motor coil resistance should also be measured and compared against specification to rule out a motor winding failure. If electrical connections and refrigerant circuit access are confirmed normal, internal compressor winding resistance checks may be necessary to determine if the compressor itself requires replacement.

Source: manufacturer service documentation.

Common causes of YEL_FLICKER_GRN_FLICKER

  1. 01

    Loose or corroded compressor TAB terminal connections

    Wiring / connection

    Poor electrical contact at the compressor TAB terminals can prevent enough current from reaching the compressor motor windings to initiate startup. Inspect the terminals for looseness, corrosion, or burn marks and reseat or clean as needed.

  2. 02

    Service valve not fully open

    Wiring / connection

    A partially or fully closed service valve restricts refrigerant flow, creating pressure conditions that place excessive load on the compressor during startup. Verify both the suction and liquid line service valves are completely open.

  3. 03

    EEV motor failure or stall

    Part replacement

    A failed Electronic Expansion Valve motor cannot properly regulate refrigerant flow into the evaporator, resulting in pressure imbalances that prevent compressor startup. Check the EEV motor coil resistance to determine if the motor winding has failed.

  4. 04

    Compressor motor winding fault

    Part replacement

    If all external causes are ruled out, the compressor itself may have an internal winding failure. Measure resistance across the compressor terminals to check for open, shorted, or grounded windings.

  5. 05

    Refrigerant pressure imbalance at startup

    Wiring / connection

    If system pressures have not equalized between the high and low sides before a restart attempt, the compressor may be unable to start against the resulting pressure differential. Allow adequate off-time between shutdown and restart attempts.

See the test procedure for each cause

Frequently asked questions about YEL_FLICKER_GRN_FLICKER

What does YEL_FLICKER_GRN_FLICKER mean on a Samsung air_conditioner?
This error code indicates a compressor starting error, meaning the outdoor unit attempted to start the compressor but could not confirm successful startup. The alternating yellow and green LED flicker pattern is the diagnostic signal for this specific fault. The three most common areas to investigate are the compressor TAB terminal connections, the service valve positions, and the EEV motor. The system will not provide cooling or heating until the fault is resolved.
Can I fix the YEL_FLICKER_GRN_FLICKER error myself?
Some steps are accessible to a knowledgeable DIYer, such as checking that the service valves are fully open and visually inspecting the compressor TAB terminal connections for obvious looseness or corrosion. However, tasks like measuring EEV motor coil resistance, checking compressor winding resistance, or handling refrigerant circuits require proper tools and, in the case of refrigerant work, EPA 608 certification. If the compressor or EEV motor needs replacement, a licensed HVAC technician should perform the repair.
Is it safe to keep running my Samsung air conditioner with this error?
The system will generally not operate while this error is active, since the compressor has failed to start. There is no immediate safety hazard from the error itself, but you should not attempt to force repeated restart cycles, as this can overheat compressor motor windings and cause additional damage. Leave the unit powered off until the root cause is identified and corrected.
How much does it cost to repair a compressor starting error on a Samsung air conditioner?
Repair costs vary significantly depending on the root cause. A simple fix like reseating loose terminal connections or opening a service valve may only involve a service call fee, typically in the range of $75 to $150. EEV motor replacement generally costs between $150 and $400 including parts and labor. Compressor replacement is substantially more expensive, often ranging from $800 to $2,000 or more depending on unit size and labor rates.
Will resetting the unit clear the YEL_FLICKER_GRN_FLICKER error?
A power reset may temporarily clear the error and allow the unit to attempt another startup, but if the underlying fault such as a bad EEV motor, closed service valve, or poor terminal connection is still present, the error will return immediately or after the next startup attempt. Resetting should only be used as a diagnostic step to confirm the fault is active, not as a substitute for identifying and correcting the actual cause.