Samsung Air Conditioner Error Code YEL_FLICKER_GRN_FLICKER
Compressor starting error
Compressor starting error
First step from the service manual
Check compressor TAB terminal connections, service valve, EEV motor
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for YEL_FLICKER_GRN_FLICKER.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What YEL_FLICKER_GRN_FLICKER means on a Samsung air conditioner
The YEL_FLICKER_GRN_FLICKER error code on a Samsung air conditioner indicates a compressor starting error, meaning the system attempted to start the compressor but failed to detect successful startup. This error is signaled by alternating yellow and green LED flickers on the indoor or outdoor unit's diagnostic display. The compressor is the core refrigerant compression component in the refrigeration circuit, and a failure to start it properly prevents the entire cooling or heating cycle from initiating. The control board monitors feedback signals from the compressor circuit to confirm startup, and when that confirmation is absent or out of specification, this code is triggered.
Three primary areas are implicated in this fault: the compressor TAB terminal connections, the service valve position, and the Electronic Expansion Valve (EEV) motor. Loose, corroded, or improperly seated TAB terminal connections at the compressor can prevent adequate electrical contact, resulting in insufficient current delivery to start the compressor motor windings. A closed or partially closed service valve restricts refrigerant flow, which can cause abnormal suction or discharge pressure conditions that prevent the compressor from starting under the resulting load. The EEV motor controls refrigerant flow into the evaporator, and a failed or stalled EEV motor can create pressure imbalances that similarly prevent compressor startup.
Diagnosis should begin at the compressor TAB terminals to verify secure, corrosion-free connections, followed by confirming both service valves are fully open. The EEV motor coil resistance should also be measured and compared against specification to rule out a motor winding failure. If electrical connections and refrigerant circuit access are confirmed normal, internal compressor winding resistance checks may be necessary to determine if the compressor itself requires replacement.
Source: manufacturer service documentation.
Common causes of YEL_FLICKER_GRN_FLICKER
- 01
Loose or corroded compressor TAB terminal connections
Wiring / connectionPoor electrical contact at the compressor TAB terminals can prevent enough current from reaching the compressor motor windings to initiate startup. Inspect the terminals for looseness, corrosion, or burn marks and reseat or clean as needed.
- 02
Service valve not fully open
Wiring / connectionA partially or fully closed service valve restricts refrigerant flow, creating pressure conditions that place excessive load on the compressor during startup. Verify both the suction and liquid line service valves are completely open.
- 03
EEV motor failure or stall
Part replacementA failed Electronic Expansion Valve motor cannot properly regulate refrigerant flow into the evaporator, resulting in pressure imbalances that prevent compressor startup. Check the EEV motor coil resistance to determine if the motor winding has failed.
- 04
Compressor motor winding fault
Part replacementIf all external causes are ruled out, the compressor itself may have an internal winding failure. Measure resistance across the compressor terminals to check for open, shorted, or grounded windings.
- 05
Refrigerant pressure imbalance at startup
Wiring / connectionIf system pressures have not equalized between the high and low sides before a restart attempt, the compressor may be unable to start against the resulting pressure differential. Allow adequate off-time between shutdown and restart attempts.
Frequently asked questions about YEL_FLICKER_GRN_FLICKER
What does YEL_FLICKER_GRN_FLICKER mean on a Samsung air_conditioner?
Can I fix the YEL_FLICKER_GRN_FLICKER error myself?
Is it safe to keep running my Samsung air conditioner with this error?
How much does it cost to repair a compressor starting error on a Samsung air conditioner?
Will resetting the unit clear the YEL_FLICKER_GRN_FLICKER error?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass