Samsung Air Conditioner Error Code YEL_ON_RED_ON
Heatsink sensor error
Heatsink sensor error
First step from the service manual
Check IPM module PIN#24,25 solder condition for cracks or short circuits
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for YEL_ON_RED_ON.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What YEL_ON_RED_ON means on a Samsung air conditioner
The YEL_ON_RED_ON error code on a Samsung air conditioner indicates a heatsink sensor error within the inverter drive system. The heatsink sensor monitors the temperature of the Intelligent Power Module (IPM), which is the component responsible for converting and regulating power to the compressor. When the sensor detects an abnormal reading, either due to a faulty sensor, wiring issue, or a problem with the IPM itself, the system triggers this fault code to protect the unit from thermal damage or electrical failure.
The primary diagnostic focus is on the IPM module, specifically pins 24 and 25, which carry the heatsink temperature sensor signal. Poor solder joints at these pins are a known cause of this fault. Hairline cracks in the solder can create intermittent or complete open circuits, causing the controller to receive no signal or an out-of-range signal from the sensor. Short circuits at these pins can similarly corrupt the sensor reading and trigger the error. Careful visual inspection under magnification and continuity testing at these points should be the first step in diagnosis.
Beyond solder joint integrity, the heatsink sensor itself may have drifted out of specification or failed entirely. Wiring and connector integrity between the sensor and the IPM board should also be evaluated. In some cases, actual overheating of the heatsink due to blocked airflow, dirty coils, or a failing fan can cause the sensor to report legitimate over-temperature conditions, which the control system flags in the same manner as a sensor fault.
Source: manufacturer service documentation.
Common causes of YEL_ON_RED_ON
- 01
Cracked or faulty solder joints at IPM pins 24 and 25
Wiring / connectionHairline cracks in the solder at IPM module pins 24 and 25 can break the sensor signal circuit, causing the controller to register a heatsink sensor fault. Inspect these joints closely under magnification for cracks, cold solder, or lifting.
- 02
Short circuit at IPM module pins 24 or 25
Wiring / connectionA short between pins 24 and 25 or to adjacent traces can corrupt the sensor signal and trigger this error. Check for solder bridges, debris, or damaged traces in this area of the board.
- 03
Failed heatsink temperature sensor
Part replacementThe heatsink sensor itself may have failed or drifted outside its specified resistance range, causing the controller to flag an invalid reading. Testing the sensor resistance at operating temperature can confirm failure.
- 04
Wiring or connector damage between sensor and IPM board
Wiring / connectionDamaged wiring, corroded connector pins, or a loose harness connection between the heatsink sensor and the IPM board can interrupt the sensor signal. Inspect the full wiring run for chafing, corrosion, or disconnection.
- 05
Actual heatsink overheating due to restricted airflow
Wiring / connectionIf airflow across the heatsink is blocked by dirt buildup, a failing fan, or obstructed vents, the sensor may be reporting a legitimate over-temperature condition rather than a sensor fault. Check fan operation and clean the heatsink fins before assuming sensor failure.
Frequently asked questions about YEL_ON_RED_ON
What does YEL_ON_RED_ON mean on a Samsung air conditioner?
Can I fix the YEL_ON_RED_ON error myself?
Is it safe to keep running my Samsung air conditioner with the YEL_ON_RED_ON error?
How much does it cost to repair the YEL_ON_RED_ON error on a Samsung air conditioner?
Will resetting my Samsung air conditioner clear the YEL_ON_RED_ON error?
78,000+ service manuals · 160,000+ error codes · 55+ brands