Error code reference
Whirlpool Microwave Error Code -F2-
Keyboard failure
Keyboard failure — error will occur if a keypad is pressed or shorted for 15 seconds.
First step from the service manual
1
Press OFF/CANCEL to clear the code; check touch panel for stuck or shorted keypads.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
MyPros+ Max
Get the full diagnostic procedure for -F2-.
- ✓Step-by-step tests with expected resistance, voltage, and continuity values
- ✓Wiring diagram references and connector pinouts from the OEM service manual
- ✓Verified part numbers when replacement is required
Get the full procedure→
$29/month · Cancel anytime · Or $9.95 3-day pass
M+
M+ Max·Whirlpool Microwave
-F2- on my Whirlpool Microwave
M+
Keyboard failure — error will occur if a keypad
From Tech Sheet W17880159, p.51:
1.Press OFF/CANCEL to clear the code; check touch panel for stuck or shorted keypads.
2.Measure control board supply voltage at the test points. Expected: 12 VDC and 5 VDC; a drop below 4.75 VDC on the logic rail points to a failed onboard regulator.
3.Inspect all connectors on the main control for corrosion, thermal stress, or backed-out pins. Reseat each connector with the power disconnected.
Part WPW10804018
Electronic control board
Related Whirlpool microwave codes
All Whirlpool microwave codes →- -F3-Thermistor failure
- 888:88Displayed after power has been interrupted to indicate a…
- E1Keypad not connected.
- E1 E5Oven user interface failure.
- E2Temperature sensor opened.
- E3Temperature sensor shorted.
- E4Oven temp too high.
- Enter clockPower failure has occurred; display flashes 'Enter clock'…
View all 141 Whirlpool microwave codes
- ERREEPROM error (listed as additional error condition…
- ERR 0Convection temperature sensor error
- ERR 1Short circuit in the MW (microwave) relay.
- ERR 2Keyboard error.
- ERR 3Key error when one of the buttons is pressed longer than 1…
- ERR 5Magnetron temperature sensor error.
- ERR 6Weight sensor calibration was not performed correctly.
- ERR 8Impossible to write to E2 PROM.
- ERR 9Options were not correctly selected.
- ERR ANo wheel detected on weight sensor.
- ERR BNo pulses from the weight sensor or frequency less than…
- ERR CFuzzy temperature sensor error
- ERR dNTC overheat protection on the magnetron is faulty (not…
- Err4Ambient temperature sensor value is outside the allowed…
- Err7Humidity sensor PWM value out of allowed range (displayed…
- ErrorGeneral error indication displayed on the control panel…
- F0Default F code
- F0-E0Default F code
- F1No display
- F1 E0Check oven user interface
- F1 E2Check microwave user interface
- F1 E3Check microwave appliance manager
- F1 E5Check microwave inverter
- F1:CFHardware configuration mismatch between electronic control…
- F1:E4Microwave relay failure.
- F1:PrSoftware type mismatch in electronic control board.
- F1.E1Relay Control Board defective.
- F10Display error.
- F1E3-0ACU Relay Failure
- F1E3-AMWO Cooling Fan Failure
- F1E6Microwave oven wave guide thermistor failure.
- F2-E0Temperature sensor opened (R=2875 ohm by spec).
- F2-E2Oven temp too high
- F2-E3Oven temp too high
- F2-E5CANCEL key drive line open.
- F2-E6CANCEL key drive line open.
- F2:E1Keyboard failure
- F2.H1Hood/light switch stuck.
- F2.H2Hood/light switch defective.
- F2.Q1User interface board (UIB) is not reading keypad inputs.
- F2KKey or foil pressed more than 1 minute.
- F2TTouch panel (LCD) pressed more than 1 minute.
- F3 E2Warming drawer sensor shorted or open (oven not equipped…
- F3-E0Door is open but latch is locked (door switch open…
- F3-E1Oven temp too high
- F3-E3Oven temp too high
- F3.H1Humidity sensor failure.
- F3.T1UIB (user interface board) thermistor failure.
- F3.T2FC (forced convection) thermistor failure.
- F3.T4Magnetron thermistor failure.
- F3CCavity temperature sensor failure.
- F3E3-0Meat Probe Failure
- F3E4Main oven powered accessory (PA) sensor open or shorted.
- F3E6Powered Accessory (PA) over temperature.
- F3E8IR sensor failure
- F3HHumidity sensor failure
- F3TTemperature sensor out of range.
- F4Microwave sensors failure
- F4-E0Meat probe shorted.
- F4:E1Magnetron temperature sensor failure (software error).
- F4E1-0Cavity NTC Failure
- F4E1-1Cavity NTC Failure
- F4E2Microwave internal (ambient) temperature sensor failure…
- F4E3Hood NTC failure
- F4E4Humidity sensor failure
- F4E5Microwave weight sensor not within normal value.
- F4E6Microwave wave-guide heat sensor failure.
- F4E7Microwave probe failure.
- F4E8Microwave Oven Humidity Sensor Error.
- F4E9MW relay synchronization Error 1
- F4EAToast NTC failure-Opened
- F4EA-0Toast NTC Failure
- F4EA-1Toast NTC Failure
- F5Microwave door switch not operating correctly (no specific…
- F5-E0Door is open but latch is locked (door switch is open…
- F5-E5Self-clean temperature 288°C (550°F) not reached within 45…
- F5-E7Self-clean latch will not unlock.
- F5E1Door latch not operating
- F5E2Open door failure
- F5E3Door and latch switch do not agree (lower oven).
- F5E4Latch not operating (lower oven).
- F5E6Oven user interface lost communication.
- F6Return line not connected
- F6 E0Oven user interface lost communication / Oven appliance…
- F6 E5No cavity size command
- F6 E6Lost communication (context
- F6 EAOver temperature (two contexts
- F6:E0Communication error between display board and electronic…
- F6E1ACU/HMI communication fault
- F6E1-0ACU/HMI Communication Fault
- F6E2Excessive oven temperature in Clean mode.
- F6E3Mini oven/warm drawer over temperature
- F6E4Lost communications with Microwave Oven Appliance Manager.
- F6E8Lost communications with Microwave Oven Appliance Manager…
- F6E9Oven appliance manager
- F7Power magnetron interrupted
- F7E0Insufficient water level, or excessive heating time to boil…
- F7E1Boiler over temperature condition.
- F7E2Boiler NTC temperature sensor out of range.
- F7E3Improper filter reset
- F7E4Conductivity sensor not connected.
- F7E9Vent error
- F8-E4Oven over temperature while door close and latch unlock.
- F8E0Low fan speed underspeed
- F8E1Low fan speed overspeed
- F8E2High fan speed underspeed
- F8E3High fan speed overspeed
- F8E5Exhaust air template detector (exhaust air temperature…
- F9Relay Control Board communications error.
- F9.QTouch communication error between UIB and touch panel board.
- F9CE2PROM Checksum error.
- F9EE2PROM empty.
- F9E0Product not wired correctly (house wiring issue, neutral…
- F9ME2PROM (Electrically Erasable Programmable Read-only…
- F9WE2PROM write error.
- FBE4MWO Cooling fan error.
- FCE1Loss of communication between Wi-Fi module and control.
- FCE2Exhaust air template detector failure (HF NTC thermistor…
- FCE3Appliance failed to connect to the wireless router.
- FCE7Appliance failed to connect to the wireless router.
- FDE3Hood fan relay failure
- FDE4MWO Cooling fan error
- Flashing colon ":"Power failure indication.
- Microwave Oven Inverter ErrorMicrowave oven inverter communication or operation error.
- MV-4903MW Relay failure (relay contact on ACU has welded closed).
- No DisplayThermal fuse, Copernicus Appliance Manager, or User…
- noCFSoftware configuration error in display board.
- NTC OPENHF NTC thermistor is open (displayed as 'NTC OPEN, CALL FOR…
- NTC OPEN, CALL FOR SERVICEHood NTC thermistor has an open circuit condition.
- NTC SHORTHF NTC thermistor is shorted (displayed as 'NTC SHORT, CALL…
- NTC SHORT, CALL FOR SERVICEHood NTC thermistor has a short circuit condition.
- PROBEMissing probe or invalid probe
- SABOven is in Sabbath Mode.
78,000+ service manuals · 160,000+ error codes · 55+ brands