Model reference
Amana 5P-2JM/P54360-50R
Air Conditioner
4 documents25 error codes22 service modes
Available documentation
Tech Tip
- Instruction Sheet - 816975420 pg
- Instruction Sheet - 818546912 pg
- Instruction Sheet - 818478312 pg
- Instruction Sheet - 816969620 pg
MyPros+ Max
Diagnose your Amana 5P-2JM/P54360-50R.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
:Flashing colon indicates a power failure has occurred.13EMAIN PCB signal not detected for 10 seconds.3EMotor failure4EWater level sensor fault5ENo drain8EMotor faultCEWater temperature faultdoorDoor is open and washer is paused.F1E4Microwave ACU PCBA failure.F2Membrane switch (touch panel) failure.F2E1Stuck key failure.F3HHumidity sensor failure.F4E4Humidity sensor error.F6Microwave relay failure (relay 4903).F8E5Exhaust air temperature detection failure.HE1Heater is over heatingHE2Heater is not heatingIEPressure switch errorLENo fillNTC OPEN, CALL FOR SERVICEHood thermistor (HF NTC) is open circuit.NTC SHORT, CALL FOR SERVICEHood thermistor (HF NTC) is shorted.OEWater sensor level faultPFPower failuretESump thermistor failureUEUnbalance detected during final spinService modes (22)
- Abbreviated White/Cottons Cycle TestWhile in Service Mode, press Delay Start (four times) followed by Start/Pause button.
- Board Output Test - LED/Switch TestEnter Board Output Test, then press the Temperature key three times followed by the Start/Pause…
- Board Output Test - Motor Output TestEnter Board Output Test, then press the Temperature key twice followed by the Start/Pause button
- Board Output Test - Valve/Pump/Heater CycleEnter Board Output Test, then press the Temperature key once followed by the Start/Pause button…
- Board Output Test (Component Cycle Time Test)While in Service Mode, press the Temperature key (Once) followed by the Start/Pause button
- Board Output Test (EEPROM Test)Press and hold the Rinse, Prewash and Delay Start buttons, followed by the Power On/Off switch
- Board Output Test (EEPROM)Press and hold the Rinse, Prewash, and Delay Start buttons, then press the Power Off switch
- Component TestWhile in Service Mode, press the Start/Pause button to cycle through
- Diagnostics / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to enter Standby mode (colon ':'…
- EEPROM Test (Board Output Test)Press and hold the Rinse, Prewash and Delay Start buttons, then press the Power On/Off switch
- LED/Switch TestEnter the Board Output Test, then press the Temperature key (three times) followed by Start/Pause…
- Motor Output TestEnter the Board Output Test, then press the Temperature key (twice) followed by Start/Pause button
- Rinse And Spin TestWhile in Service Mode, press Delay Start (seven times) followed by Start/Pause button
- Self-diagnostic (Touch Panel and Microcomputer Board Test)["Depress the OFF/CANCEL button while opening the door.","While still depressing the OFF/CANCEL…
- Self-diagnostic / Touch Panel and Microcomputer Board Test["1
- Self-diagnostic test mode["1
- Self-Diagnostic Test Mode (Touch Panel and Microcomputer Board Test)["1
- Service Mode1
- Spin TestWhile in Service Mode, press Delay Start (six times) followed by Start/Pause button
- Thermistor TestWhile in Service Mode, press Delay Start (two times) followed by Start/Pause button
- Unbalance TestWhile in Service Mode, press Delay Start (three times) followed by Start/Pause button
- White/Cottons Cycle TestWhile in Service Mode, press Delay Start (five times) followed by Start/Pause button.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass