Model reference
Amana OS-125-4/P96237-4F
Furnace
1 document23 error codes11 service modes
Available documentation
Tech Sheet
- Tech Sheet - 820512424 pg
MyPros+ Max
Diagnose your Amana OS-125-4/P96237-4F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (23)
CodeMeaning
:Power failure indication; the colon flashes on the display after a power…F1E1Indicates a CCU (Cycle Control Unit) problem.F1E4MW relay failure (Relay 4903 on PCBA).F2Membrane switch failure.F2E1Touch panel failure.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F3HHumidity sensor failure.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6Microwave relay failure.F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…L2Low L2 voltage (less than 50V) detected at the CCU.NTC OPEN, CALL FOR SERVICEHood thermistor is open circuit.NTC SHORT, CALL FOR SERVICEHood thermistor is shorted.PFPower failure occurred while the dryer was running.Service modes (11)
- Customer-Focused Dryness Level Adjustment1
- Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Self-diagnostic test mode["1
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Software Version Display1
- Touch Panel and Electronic Control Self-Diagnostic Test Mode["1
- Touch Panel and Microcomputer Board Self-Diagnostic Test["Depress the CANCEL button while opening the door.","While still depressing the CANCEL button…
- Touch Panel and Microcomputer Board Self-Diagnostic Test Mode["Depress and hold the CANCEL•OFF button.","While still holding CANCEL•OFF, open the door.","While…
- Touch Panel and PCBA Self-Diagnostic Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to reach standby (colon ':'…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass