10 documents50 error codes13 service modes
Available documentation
Tech Sheet
- tech sheet w10187806 reva20 pg
- Tech Sheet - W11642952 - Rev A2 pg
- Tech Sheet - W10221560 - Rev A10 pg
- Tech Sheet - W10268745 - Rev A10 pg
- Tech Sheet - 820586912 pg
Service Manual
- Service Manual - SAM003523 pg
- Service Manual - SAM001623 pg
- Service Manual - SAM002823 pg
- Service Manual - SAM003023 pg
Quick Reference
- Quick Reference Manual32 pg
MyPros+ Max
Diagnose your Amana OS-150/P96317-1F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (50)
CodeMeaning
:Flashing colon indicates a power failure has occurred.1-1Control detected K2 pilot relay stuck closed.1-2Damaged or corrupted memory on control board or incompatible software…1-3Control detected stuck key(s) in keypad or keypad connection.10-1Dispenser electrical problem10-2Vent wax motor electrical problem.10-3Drying fan error2-1User interface stuck key or short circuit(s) in keypad or in control's input…2-2User interface cannot communicate with main control3-1Open temperature sensing circuit3-2Shorted temperature sensing circuit3-3OWI/thermistor sensor failed calibration.4-3Wash motor not running5-1Door stuck open5-2Door stuck closed6-1Inlet water6-2Inlet water6-3Inlet water6-4Inlet water6-6Inlet water6-7Disconnected or damaged flowmeter.6-8Inlet water7-1Heating7-1 (flowmeter)Disconnected or damaged flowmeter.7-2Heating8-1Draining8-2Draining8-3Draining8-5Drain stuck on9-1DiverterView all 50 error codes
9-2Diverter stuck on9-3Diverter disk missing from sump.9-4Lower spray arm errorerror1Shorted sensor circuit.error2Open sensor circuit.error3On the cooling mode, sensor's Vout was not less than 4.7V within 3 minutes.error4On the way to sensing, the door was opened.F1E0Internal board failure.F1E1Internal board failure.F1E2A/D error(s).F2Touch panel failure.F2E1Shorted keypad.F3E0Oven sensor opened, oven sensor shorted, bake/broil range over temperature, or…F3HHumidity sensor failure.F5E0Door and switches do not agree (Clean mode).F5E1Door latch not operating (Clean mode).F6MW relay failure (Relay 4903 contact may have welded closed).F6E1Oven over temperature when heating.F9E0Miswired house or miswired range.No DisplayControl not operational.
Service modes (13)
- Clear Customer Error HistoryDuring Service Diagnostics Cycle interval where Hi Temp LED is on (interval 22), press Hi Temp key…
- Customer Cycle Rapid AdvanceAfter starting a customer cycle, press HIGH TEMP
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Error History ReadingEnter Service Diagnostics Cycle. Error codes are displayed in intervals 24 (Error 1
- Rapid Advance Mode (Customer Cycles)After starting a customer cycle, press HIGH TEMP
- Rapid Advance Mode (Cycle Operation)After starting a cycle, press HI TEMP
- Rapid Advance Mode (during active cycle)Press HI TEMP
- Rapid Advance Mode (in-cycle)After starting a cycle, press HI TEMP
- Self-diagnostic / Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- Self-Diagnostic Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…
- Service Diagnostics Error History ReadoutAfter entering Service Diagnostics Cycle, errors are displayed in intervals 24 (Error 1
- Touch Panel and Electronic Control Self-Diagnostic Test Mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…
Full entry steps, exit procedures, and test sequences are available in Max.