Error codes (47)
CodeMeaning
1-1Control detected K2 pilot relay stuck closed.1-2Damaged or corrupted memory on control board, or incompatible software…10-1Dispenser electrical problem; loose connection in dispenser circuit and/or open…10-2Vent wax motor electrical problem; loose connection in vent circuit and/or open…10-3Drying fan error; loose connection in fan circuit and/or open fan motor.2-1Stuck key(s) detected in keypad or keypad connection.2-2User interface cannot communicate with the main control board; incorrect…3-1Open connector or component in temperature sensing circuit; open or faulty…3-2Incoming water temperature above 167°F (75°C), or shorted connection/component…3-3OWI failed calibration.4-3Wash motor not running due to loose connection in wash motor circuit and/or…5-1Door stuck open; door was not latched within 3 seconds of pressing Start/Resume…5-2Door stuck closed; control programmed to not start if it suspects door switch…6-1Low/no water (mechanical problem); no water supply to dishwasher or various…6-2Fill valve electrical problem; loose connection in fill valve circuit and/or…6-3Suds/air in pump; too many suds, captured wash water, water leak, or missing…6-4Float switch open; overfill switch stuck in overfill position and/or dishwasher…6-7Disconnected or damaged flowmeter.6-8Regen valve electrical problem; loose connection in regen valve circuit and/or…7-1No heat; control programmed to disable heater but continue running cycles if it…7-2Heater stuck on; heater drive circuit on the control is faulty.8-1Slow drain; obstructed drain hose or path, or drain pump impeller fractured.8-2Drain motor electrical problem; loose connection in drain motor circuit and/or…8-3Drain stuck on; drain motor drive circuit on the control is faulty.9-1Can't find diverter position; corroded or loose connection in diverter…9-2Diverter stuck on; diverter drive circuit on the control is faulty.9-3Control detected diverter disk in sump is missing.9-4Lower spray arm error; mechanical blockage or jammed lower spray arm, or…F1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; this…View all 47 error codes
F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1No voltage detected at the heater relay; this fault code appears ONLY when in…F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication error from CCU to UI; communication between the CCU and UI has…FCE1WiFi Module communications lost.LLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000…L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.
Service modes (14)
- Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
- Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…
- Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass