Model reference
Amana RC17-P1198612M
Microwave
11 documents26 error codes11 service modes
Available documentation
Service Manual
- Cavity Replacement Instructions for 2 – Tube Models12 pg
- Service Manual - RS222000160 pg
Tech Sheet
- Commercial Microwave—Technical Information13 pg
- Tech Sheet - 1602596616 pg
- Tech Sheet - 1602281616 pg
- Tech Sheet - W10918869 Rev E6 pg
Bulletin
- Technical Bulletin - TCM-0008-B HV Board 107632071 pg
- TechnicalBulletin - TCM-0002A-B - Clean Filter Feature3 pg
- Technical Bulletin - ITCM-0017-B Seal Holes in Cavity Bottom when replacing Lower Antenna Motor1 pg
Tech Tip
- Instruction Sheet1 pg
- Instruction Sheet2 pg
MyPros+ Max
Diagnose your Amana RC17-P1198612M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (26)
CodeMeaning
CALL SErvAmperage monitoring system on H.VCSCurrent SenseDoorDoor Interlock Primary Switch fault.Err1Failed H.VErr2Failed H.VErr3Failed H.VErr4Failed H.VErr5Shorted Touch Panel.Err6Failed H.VF3E0Refrigerator/Main compartment (Z1) thermistor short or open circuit.F3E1Freezer/Main compartment (Z1) thermistor short or open circuit.F3E2Refrigerator Evaporator thermistor short or open circuit.F3E3Freezer Evaporator thermistor short or open circuit.F3E4Deli compartment (Z2) thermistor short or open circuit.F3E5Crisper (Z3) thermistor short or open circuit.FDE0Ice maker tray thermistor short or open circuit.FDEAIce Maker Jammed (cannot find Homing or end of harvest location).HIHigh line voltage detectedHOTThermal protection activated due to open TCO, inoperative blower motor…LOLow line voltage detectedOPOpen circuit detected on thermistor.PCE1Checksum errorPCE5Communication failure between high voltage board, low voltage board, or…PCE6Communication failure between high voltage board, low voltage board, or…S1Watchdog circuit detects a shorted membrane touch panel.SHShort circuit detected on thermistor.Service modes (11)
- CALL SErv Reset["Unit must be in OFF condition or INITIAL power up mode.","Oven door must be closed.","Press…
- Door Cycles and Magnetron Hours["1
- Extended Memory Board Test["1
- H.V. System Test["1
- Option Programs (All Models Except WDYRC)["1
- Programming Mode (DQ & MC models)["1
- Programming Mode (RC models)["1
- Service Diagnostics Mode["Press the pulsing JennAir logo to wake up the UI.","Press the middle zone key.","Press CONNECT…
- Service Test Mode["Unit must be in OFF condition or INITIAL power up mode.","Oven door must be closed.","Press…
- Service Test Mode (All Models Except WDYRC)["1
- Showroom Mode["Press and hold top and bottom zone icons simultaneously for 3 seconds."]
Full entry steps, exit procedures, and test sequences are available in Max.