Model reference
Amana RC27-P1198608M
Microwave
9 documents25 error codes10 service modes
Available documentation
Service Manual
- Service Manual - RS222000160 pg
Tech Sheet
- Tech Sheet - 1602596616 pg
- Tech Sheet - 1602281616 pg
- Tech Sheet - W10918869 Rev E6 pg
Bulletin
- Technical Bulletin - TCM-0008-B HV Board 107632071 pg
- Technical Bulletin - TCM-0028-B Replacing Lower Antenna Motor or Oven Tray1 pg
Tech Tip
- Instruction Sheet2 pg
- Instruction Sheet1 pg
- Instruction Sheet2 pg
MyPros+ Max
Diagnose your Amana RC27-P1198608M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
CSCurrent SenseDoorDoor interlock primary switch fault.Err1Failed H.VErr2Failed H.VErr3Failed H.VErr4Failed H.VErr5Shorted Touch PanelErr6Failed H.VF3E0Refrigerator/Main compartment (Z1) thermistor short or open circuit.F3E1Freezer/Main compartment (Z1) thermistor short or open circuit.F3E2Refrigerator Evaporator thermistor short or open circuit.F3E3Freezer Evaporator thermistor short or open circuit.F3E4Deli compartment (Z2) thermistor short or open circuit.F3E5Crisper (Z3) thermistor short or open circuit.FDE0Ice maker tray thermistor short or open circuit.FDEAIce Maker Jammed (cannot find Homing or end of harvest location).HIHigh line voltage detectedHOTMagnetron overheating condition detected.LOLow line voltage detectedOPOpen circuit detected on thermistor.PCE1Checksum errorPCE5Communication failure between high voltage board, low voltage board, or…PCE6Communication failure between high voltage board, low voltage board, or…S1Watchdog circuit detects a shorted membrane touch panel.SHShort circuit detected on thermistor.Service modes (10)
- Door Cycles and Magnetron Hours["1
- Extended Memory Board Test["1
- H.V. System Test["1
- Option Programs (All Models Except WDYRC)["1
- Programming Mode (DQ & MC models)["1
- Programming Mode (RC models)["1
- Service Diagnostics Mode["Press the pulsing JennAir logo to wake up the UI.","Press the middle zone key.","Press CONNECT…
- Service Test Mode["Unit must be in OFF condition or INITIAL power-up mode.","Close the oven door.","Press the Hidden…
- Service Test Mode (All Models Except WDYRC)["1
- Showroom Mode["Press and hold top and bottom zone icons simultaneously for 3 seconds."]
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands