Model reference
Bradford White RG2PV50H
Water Heater
1 document15 error codes
Available documentation
Service Manual
- PV Series Power Vent Gas Water Heaters SERVICE MANUAL Troubleshooting Guide and Instructions for Service48 pg
MyPros+ Max
Diagnose your Bradford White RG2PV50H.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (15)
CodeMeaning
1 flashHeartbeat/stand-by mode indicating thermostat is calling for heat with a weak…2 flashPressure switch not working3 flashPressure switch or blower temperature switch not working4 flashExcessive tank temperature; ECO (Energy Cut Out) limit reached5 flashUndesired/false pilot flame present when pilot valve is not open.6-1 flashFailed to light pilot6-2 flashPressure switch or blower temperature switch opened during burner operation6-3 flashPilot flame extinguished during operation6-4 flashUndesired/false pilot flame sensed out of sequence7 flashFlammable vapor sensor or simulated resistive device fault detected8-1 flashFlammable vapor sensor or simulated resistive device out of specification…8-2 flashTemperature sensor fault8-3 flashGas valve electronics fault detected8-4 flashGas valve fault detectedNoneNo electrical power to the control; power switch is in OFF position or supply…Related Bradford White water heater models