Model reference
Caloric DCR225-1C-OS
Dishwasher
2 documents44 error codes9 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11756689 - Rev A2 pg
Tech Tip
- Instruction Sheet32 pg
MyPros+ Max
Diagnose your Caloric DCR225-1C-OS.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (44)
CodeMeaning
F10E1Overfill/Float Switch Open.F10E2Vent Wax Motor Electrical Problem.F10E3Drying Fan Electrical Problem.F10E4Diverter Cannot Find Positions.F10E5Diverter Leak Detected.F1E1Indicates a CCU (Cycle Control Unit) problem.F1E2ControlF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatchF3E1Outlet thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Outlet thermistor has shorted; temperature above 250°F (<500 ohms).F3E5Compressor and outlet thermistors are open; will occur if the P14 connector is…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF3E8Compressor sensor is open; this fault code will stop the dryer.F3E9Compressor sensor has shorted; this fault code will stop the dryer.F4E1No voltage detected at the heater relay; appears only in Diagnostic Test Mode.F4E2RIF Filter Plugged.F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5E1Door SwitchF5E2Door SwitchF5E3Thermistor/OWIF6E1Communication between the CCU and UI has not been detected (UI to CCU…F6E2Communication between the CCU and UI has not been detected (CCU to UI…F7E1HeaterF7E2HeaterF7E4Very Low Water/Suds/Air in Pump.F8E1Inlet WaterF8E2Inlet WaterF8E3OWIView all 44 error codes
F8E4HeaterF8E5Inlet WaterF8E6Flow Meter Failed.F9E1Drain system errorF9E2DrainingF9E4Tub Light Failure.FAE1Overfill/Float Switch Open (alternate display for F10E1).FAE2Vent Wax Motor Electrical Problem (alternate display for F10E2).FAE3Drying Fan Electrical Problem (alternate display for F10E3).FAE4Diverter Cannot Find Positions (alternate display for F10E4).FAE5Diverter Leak Detected (alternate display for F10E5).L2Low L2 voltage (less than 50V) detected at the CCU.LFLint filter has been removed from running position.PFPower failure occurred while the dryer was running.
Service modes (9)
- Clear Error Code HistoryWhile in Service Diagnostic Mode, press and hold the 1st button for 5 seconds.
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Error Code History DisplayWhile in Service Diagnostic Mode, momentarily press the 3rd button to display the next error code
- Install Diagnostics["Activate Service Diagnostic Mode first (see Service Diagnostic Mode entry).","Ensure all of step…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Service Test CycleWhile in Service Diagnostic Mode, momentarily press the 2nd button.
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface TestWhile in Service Diagnostic Mode, momentarily press the 1st button.
Full entry steps, exit procedures, and test sequences are available in Max.